Baldor VS1MD instruction manual H91 Parameter Read H92 Parameter Write Range Default

Models: VS1MD

1 168
Download 168 pages 41.14 Kb
Page 101
Image 101

H91 Parameter Read

H92 Parameter Write

Range: 0-1

Default: 0

Access Configurable

H91 Copies the parameters from the drive and saves them into a remote keypad.

H92 Copies the saved file in a remote keypad and writes it to the drive.

H93 Parameter Initialize

Range: 0 - 5

Default: 0

Access Configurable

This parameter is used to initialize the drive settings back to their factory default values.

0 = No Action

1 = All parameters set to factory defaults

To reset individual groups only and not all parameters select one of the following:

2

= P Group Parameter Reset

3

= F Group Parameter Reset

4

= H Group Parameter Reset

5

= t Group Parameter Reset

Press the ENTER key after setting H93. H93 will be displayed again after initialization.

H94 Password Register

Range: 0-FFFF

Default: 0

Access Tunable

See Also:

H95

This parameter is used to assign a password for the drive.

H95 Parameter Lock

Range: 0 -FFFF

Default: 0

Access Tunable

See Also:

H94

This parameter is able to lock or unlock parameters by typing the password registered in H94.

Parameter Descriptions

7-57

Page 101
Image 101
Baldor VS1MD H91 Parameter Read H92 Parameter Write Range Default, H93 Parameter Initialize Range 0 Default