The first parameter of each group, with the exception of the “Display Group”, is a special parameter called a “Jump Code”. The parameter can be used to jump to a specific parameter within a group without having to scroll through the parameters using the up and down arrows. Once the Jump Code is programmed, the drive will save the setting for future use, but this can always be reprogrammed to jump to a different parameter.

The following example illustrates the use of a Jump Code to jump to parameter P38.

Table 6.6 – Using the Jump Code

Procedure

Sample Display

Step 1. From the operation mode, press and hold down the ENTER key for at least two seconds to change the drive to the programming mode. The “PROG” LED will illuminate indicating that the drive is in programming mode. The drive will display the first parameter of the “Display” group.

Step 2. Press the right arrow to change to the “Parameters” group.

Step 3. Press the ENTER key to edit P0 (Jump Code).

Step 4. Press the UP arrow seven times until the display indicates an “8”.

Step 5. Press the left arrow one time such that the next digit is displayed. It will be displayed brighter than the previous digit.

Step 6. Press the UP arrow three times such that the display indicates the parameter number.

Step 7. Press the ENTER key to accept the value. The value will be saved in the Jump Code (P0) for future use and the desired parameter will immediately be displayed.