Baldor VS1MD F54 Overload Warning Level Range, Default Access Tunable, F56 Default

Models: VS1MD

1 168
Download 168 pages 41.14 Kb
Page 80
Image 80

F54 Overload Warning Level

Range:

30-150 [%]

 

 

Default: 150

Access Tunable

See Also: P32, t32, t33, F55

Sets the amount of current to issue an alarm signal at a relay or digital output terminal (see parameters t32 and t33). The value is set as a percentage of P32 – Motor Rated Current.

Select an output terminal for this function between MO (Digital Output) and 3A~C (Relay Output). If selecting MO as the output terminal, set t32 = 5 (Overload: OL).

F55 Overload warning time

Range:

0-30 [sec]

 

 

Default: 10

Access tunable

See also: P32, t32,t33, F54

This parameter issues an alarm signal when the current greater than F54 – Overload warning level flows to the motor for F55 – Overload warning time.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F56

Default:

180￿

 

￿￿￿￿￿￿￿￿￿￿￿￿

 

￿

 

 

 

 

 

 

 

 

 

Overload trip enable

 

 

 

 

 

 

 

 

 

 

 

Range:

0 - 1

 

 

 

 

 

 

 

 

 

 

 

 

 

Default:

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Access

Tunable

 

 

 

 

 

 

 

 

 

 

 

See Also:

F57, F58

 

 

 

 

 

 

 

 

 

 

 

When set to a 1 = enabled, this parameter turns off the inverter output when

 

the motor is overloaded. Overload level and time are set in F57 and F58

 

respectively.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F57

Overload trip level

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Range:

30-200 [%]

 

 

 

 

 

 

 

￿￿￿

 

Access

Tunable

 

 

 

 

 

 

 

 

 

See Also:

P32, F56, F58

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This parameter sets the amount of overload current before the drive trips. The￿￿￿￿￿￿value￿￿￿￿￿￿￿￿is a percentage of P32 – Motor rated current.

7-36

VS1MD AC Drive User Manual