USER’S GUIDE
INTERFACE SPECIFICATIONS
Bi-directional Parallel Interface
Interface Connector
A shielded cable that is IEEE 1285 compliant with the following pin assignment should be used. Most existing parallel cables support bi- directional communication, but some might have incompatible pin assignments or may not be IEEE 1284 compliant.
18 15 12 9 6 3 1
36 | 33 | 30 | 27 | 24 | 21 | 19 |
|
|
|
|
| ||
Fig. | Parallel Interface Connector |
|
|
|
|
| |||||||
Pin Assignment |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
| |
Pin No. | Signal |
|
|
|
|
| Pin No. | Signal | |||||
|
|
|
|
|
|
|
|
|
|
|
| ||
1 | DATA STROBE |
| 19 |
| Twisted pair ground | ||||||||
2 | DATA 0 |
|
|
| 20 |
| Twisted pair ground | ||||||
3 | DATA 1 |
|
|
| 21 |
| Twisted pair ground | ||||||
4 | DATA 2 |
|
|
| 22 |
| Twisted pair ground | ||||||
5 | DATA 3 |
|
|
| 23 |
| Twisted pair ground | ||||||
6 | DATA 4 |
|
|
| 24 |
| Twisted pair ground | ||||||
7 | DATA 5 |
|
|
| 25 |
| Twisted pair ground | ||||||
8 | DATA 6 |
|
|
| 26 |
| Twisted pair ground | ||||||
9 | DATA 7 |
|
|
| 27 |
| Twisted pair ground | ||||||
|
|
|
|
|
|
|
|
|
|
|
|
| |
10 | ACKNLG |
|
|
| 28 |
| Twisted pair ground | ||||||
11 | BUSY |
|
|
| 29 |
| Twisted pair ground | ||||||
12 |
|
|
|
|
|
|
|
|
|
|
|
|
|
PE |
|
|
|
|
| 30 |
| INPUT PRIME RET | |||||
|
|
|
|
|
|
|
|
|
|
|
|
| |
13 | SLCT |
|
|
|
|
| 31 |
| INPUT PRIME | ||||
|
|
|
|
|
|
|
|
|
| ||||
14 | AUTO FEED |
|
|
| 32 |
| FAULT | ||||||
15 | N.C. |
|
|
|
|
| 33 |
| N.C. | ||||
16 | 0V |
|
|
|
|
| 34 |
| N.C. | ||||
17 | 0V |
|
|
|
|
| 35 |
| N.C. | ||||
18 |
|
|
|
|
|
|
|
|
|
| |||
+5V |
|
|
|
|
| 36 |
| SELECT IN | |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|