Cisco Systems 6500 manual Transmit dBm Receive dBm Product Number, Specification

Models: 6500

1 262
Download 262 pages 31.67 Kb
Page 227
Image 227

Appendix B Pluggable Transceiver Modules

10-GB Transceivers

Table B-13lists the fiber loss budgets for the 10-GB XENPAK transceivers.

Table B-13

Fiber Loss Budgets for the 10-GB XENPAK Transceivers

 

 

 

10-GB XENPAK Transceiver

Transmit (dBm)

Receive (dBm)

Product Number

 

 

 

 

 

XENPAK-10GB-SR

–1.21(maximum)

–1 (maximum)

 

 

–7.3 (minimum)

–9.9 (minimum)

 

 

 

XENPAK-10GB-LX4

–0.5 per lane (maximum)

–0.5 per lane (maximum)

 

 

–6.75 per lane (minimum)

–14.25 per lane (minimum)

 

 

 

XENPAK-10GB-LR

0.5 (maximum)

0.5 (maximum)

XENPAK-10GB-LR+

–8.2 (minimum)

–14.4 (minimum)

 

 

 

XENPAK-10GB-LRM

0.5 (maximum)

0.5 (maximum)

 

 

–6.5 (minimum)

–8.4 (minimum) (in average)

 

 

 

6.4 (minimum) (in Optical Modulation

 

 

 

Amplitude (OMA))2

XENPAK-10GB-LW

0.5 (maximum)

0.5 (maximum)

 

 

–8.2(minimum)

–14.4 (minimum)

 

 

 

XENPAK-10GB-ER

4.0 (maximum)

–1.0 (maximum)

XENPAK-10GB-ER+

–4.7 (minimum)

–15.8 (minimum)

 

 

 

XENPAK-10GB-ZR

4.0 (maximum)

–7.0 (maximum)

 

 

0 (minimum)

–24.0 (minimum)

 

 

 

 

1.The launch power shall be the lesser of the class 1 safety limit or the maximum receive power. Class 1 laser requirements are defined by IEC 60825-1: 2001.

2.Both the average and the OMA specifications must be met simultaneously.

Table B-14lists the physical and environmental specifications for the XENPAK transceivers.

Table B-14 10-GB XENPAK Transceiver Physical and Environmental Specifications

Item

Specification

 

 

Dimensions (H x W x D)

0.47 x 1.42 x 4.76 in. (18 x 36 x 121 mm)

 

 

Operating temperature

32° to 104°F (0° to 40°C)

Storage temperature

-40° to 167°F (–40° to 75°C)

 

 