Cisco Systems 6500 manual FAN-MOD-4HS-300 CFM

Models: 6500

1 262
Download 262 pages 31.67 Kb
Page 29
Image 29

Chapter 1 Catalyst 6500 Series Switch Chassis Overview

Catalyst 6504-E Switch

Table 1-6 Catalyst 6504-E Switch Specifications

Item

Specification

 

 

Environmental

 

Temperature, operating

Certified for operation: 32° to 104°F (0° to 40°C)

 

Designed and tested for operation: 32° to 130°F (0° to 55°C)

 

Note The Catalyst 6500 series switches are equipped with internal air

 

temperature sensors that are triggered at 104°F (40°C) generating a

 

minor alarm and at 131°F (55°C) generating a major alarm.

Temperature, nonoperating

–4° to 149°F (–20° to 65°C)

and storage

 

Thermal transition

0.5°C per minute (hot to cold)

 

0.33°C per minute (cold to hot)

 

 

Humidity (RH), ambient

10% to 85%

(noncondensing) operating

 

Humidity (RH), ambient

5% to 95%

(noncondensing)

 

nonoperating and storage

 

Altitude, operating

Certified for operation: 0 to 6500 feet (0 to 2000 m)

 

Designed and tested for operation: –200 to 10,000 feet (–60 to 3000 m)

 

 

Physical Characteristics

 

Dimensions (H x W x D)

8.7 x 17.5 x 21.6 in. (22.09 x 44.45 x 54.86 cm).

 

Chassis requires 5 RU.

 

Chassis can be mounted in equipment racks that meet ANSI/EIA 310-D

 

and ETS 300-119 standards.

Weight

Chassis only: 27 lb (12.25 kg).

 

Chassis fully configured with 2 supervisor engines, 2 modules, and

 

2 AC-input power supplies: 97 lb (43.99 kg).

 

 

Airflow

FAN-MOD-4HS—300 CFM

 

Note To maintain proper air circulation through the Catalyst switch

 

chassis, we recommend that you maintain a minimum 6-inch (15 cm)

 

separation between a wall and the chassis air intake or a wall and the

 

chassis air exhaust. You should also allow a minimum separation of

 

12 inches (30.5 cm) between the hot air exhaust on one chassis and

 

the air intake on another chassis. Failure to maintain adequate air

 

space can cause the chassis to overheat and the system to fail. On

 

Catalyst chassis in which the airflow is from front to back, the

 

chassis may be placed side-by-side.

 

 

Catalyst 6500 Series Ethernet Modules Installation Guide

 

OL-6265-04

1-13

 

 

 

Page 29
Image 29
Cisco Systems 6500 manual FAN-MOD-4HS-300 CFM