Chapter1 Product Overviews
Cisco MGX 8880 Media Gateway
APS Assembly
For both equipment and fiber protection, the 1+1 card and APS line redundancy con figuration requires
that an APS connector link two optical back cards: an active card and a standby card. Figure1-50 shows
an example of two back cards installed in an APS connector. When the two back cards are linked to an
APS connector, they form an APS assembly. The APS assembly is installed in the rear of the switch. For
more information, see Tabl e 4-4.
Figure1-50 APS Assembly Example for MGX 8880
Two APS connectors are available for the Cisco MGX 8880 switch: Cisco Part Number
MGX-8850-APS-CON or MGX-APS-CON. Tab le 1-1 3 lists module support for APS connectors.
116510
Table1-13 APS Connector Support for MGX 8880 Modules
Module MGX-8850-APS-CON MGX-APS-CON
AXSM-1-2488/B Yes Yes
AXSM-4-622/B Yes Yes
AXSM-16-155/B Yes Yes
SRME/B No No