5-139
Cisco MGX 8800/8900 Series Hardware Installation Guide
Releases 2 - 5.2, Part Number OL-4545-01, Rev. H0, May 2006
Chapter5 Installing the Cisco MGX Switch or Gateway
First Time Power On Procedure for MGX Switches
Step5 Insert in the back cards and console port cable for the primary PXM controller card. For example, on an
MGX 8850 (PXM45) chassis, the PXM-UI-S3 or PXM-UI-S3/B back card su pports the PXM45 front
(controller) card. For this example, the primary PXM full-height card will be in slot 7 and 23 when
viewed from the front of the chassis. Then insert the half-height PXM-UI-S3 or PXM-UI-S3/ B back card
in back of the chassis, in the top bay behind slot 7. The PXM-HD (hard disk) card would be inserted in
the back of the chassis, in the lower bay behind slot 23.
Step6 Insert the primary PXM front card.
Step7 Through the console port connection, monitor the primary PXM c ard as it comes up to Active status.
When the card is Active, the prompt will appear like n.7.PXM.a>.
Use display environment statistics or alarm commands (dspenvalms or dspenvstats) to ensure that
all components such as power supplies and fans are running. See the following example:
M8850_LA.7.PXM.a > dspenvalms
M8850_LA System Rev: 05.00 Apr. 26, 2004 19:52:30 GMT
MGX8850 Node Alarm: MAJOR
ENVIRONMENTAL ALARM STATE INFO ^Notification Disabled
Alarm Type Unit Threshold DataType Value State
---------------- ---- -------------- -------- ---------- -------------
Temperature <= 50 Celsius 34 Normal
Power Supply A1 none None none Normal
Power Supply A2 none None none Normal
Power Supply A3 none None none Missing
DC Voltage A 42 to 58 VoltsDC 49 Normal
Power Supply B1 none None none Missing
Power Supply B2 none None none Missing
Power Supply B3 none None none Missing
DC Voltage B 42 to 58 VoltsDC 0 Normal
Top Fan Tray 1 >= 2000 RPM 3594 Normal
Top Fan Tray 2 >= 2000 RPM 3534 Normal
Top Fan Tray 3 >= 2000 RPM 3594 Normal
Top Fan Tray 4 >= 2000 RPM 3498 Normal
Top Fan Tray 5 >= 2000 RPM 3414 Normal
Top Fan Tray 6 >= 2000 RPM 3558 Normal
Table5-9 Slot Compatibility for MGX Chassis and Their PXM and SRM Cards
MGX Switch or Gateway
Processor Switch Module (PXM)
Type and Slots Service Resource Module (SRM) Slots
MGX 8230 multiservice gateway PXM1, Slots 1 and 2 Slots 7 and 14
MGX 8250 multiservice gateway PXM1, Slots 7, 8, 23, and 24 Slots 15, 16, 31, and 32
MGX 8830 multiservice switch PXM1E, Slots 1 and 2 Slots 7 and 14
MGX 8850 (PXM1) multiservice switch PXM1, Slots 7, 8, 23, and 24 Slots 15, 16, 31, and 32
MGX 8850 (PXM1E) multiservice switch PXM1E, Slots 7, 8, 23, and 24 Slots 15, 16, 31, and 32
MGX 8850 (PXM45) multiservice switch PXM45, Slots 7, 8, 23, a nd 24 Slots 15, 16, 31, and 32
MGX 8880 media gateway PXM45, Slots 7, 8, 23, and 24 Slots 15, 16, 31, and 32
MGX 8950 core multiservice switch PXM45, Slots 7, 8, 23, and 24 Slots 9, 10, 25, and 26 are reserved for
XM60 cards