Chapter6 Maintaining the Cisco MGX Switch or Gateway
Installing or Removing Redundancy Connectors
Step4 Place the RCON assembly over the RCON mounting bar, positioning the RCON alignment flange over
the top edge of the bar and the RCON alignment pins through holes in the bar (See Figure 6-13).
If you are installing the 1:5 RCON, there is a single mou nting position on the mounting bar.
If you are installing the 1:3 RCON, there are two mounting posit ions on the mounting bar, offset by
one slot. The 1:3 RCON in Figure 6-13 is shown in the left-hand mounting location.
Note Be careful not to bend or damage the pins on nearby back ca rd connectors.
Figure6-13 MGX 8850/B RCON Installation
Step5 Tighten the two RCON fasteners, first by hand and then using a screwdriver.
Step6 Install additional RCONs, if desired. You can install up to four RCONs, on the left and right-hand side
of the top and bottom bay.
Step7 Reinstall all back cards.
1Mounting bar for RCON 5Alignment holes for RCON
2Alignment flange on 1:5 RCON assembly 6Alignment flange on 1:3 RCON assembly
3Mounting screw on 1:5 RCON assembly 7Mounting screw on 1:3 RCON assembly
4Left mounting location for 1:3 RCON