2-26
Cisco MGX 8800/8900 Series Hardware Installation Guide
Releases 2 - 5.2, Part Number OL-4545-01, Rev. H0, May 2006
Chapter2 Illustrated Card List for MGX Switches and the MGX 8880 Media Gateway
Front Cards
Table 2 -13 describes the LEDs on the CESM cards.
Module Configurations
The CESM supports the following module configurations:
Standalone.
1:N card set redundancy, without bulk distribution.
1:N card set redundancy, with bulk distribution—For line redundancy to be supported in this
configuration, there must be redundant PXM1E or PXM45 cards and redundant SRME cards. The
APS connector must be installed between the SRME cards.
Bulk distribution.
Note For module configuration information, refer to Chapter4, “Planning for Card Redunda ncy, Line
Redundancy, and Bulk Distribution”.
Table2-13 CESM LEDs
LED Status Description
ACT Green The CESM card set (front card and back card) is in active
state.
STBY Yellow or
blinking yellow
One of the following conditions exists:
The CESM is in Standby mode.
The CESM is in mismatch state.
The CESM DSPs are currently involved in the CESM
bootup process.
FAIL Red When this LED is solid red and the ACT and STBY LEDs
are off, one of the following conditions exists:
The module is in Reset mode.
The module has failed.
The card set is not complete (no back card).
PORT 1 through
PORT 8
Green The port is active with no alarms detected.
Red The port is active and a local alarm has been detected.
Yellow The port is active and a remote alarm has been detected.
Off The port is not configured, or the card set is configured as
a redundant card set and is in Standby mode.