5-91
Cisco MGX 8800/8900 Series Hardware Installation Guide
Releases 2 - 5.2, Part Number OL-4545-01, Rev. H0, May 2006
Chapter5 Installing the Cisco MGX Switch or Gateway
Installing the MGX 8950 Switch
Warning
Do not touch the power supply when the power cord is connected. For systems with a power switch,
line voltages are present within the power supply even when the power switch is off and if the power
cord is connected. For systems without a power switch, line voltages are present within the power
supply when the power cord is connected.
Statement 4
Connect AC Power to the Switch
To connect AC power to the MGX 8950 switch, use AC power cords with the following types of AC wall
plugs:
30A NEMA L620, 3-prong plug (North America), shown in Figure 5-57.
Figure 5-57 AC Power Cable (North America)
30A IEC 309 plug (Europe, Australia, New Zealand), shown in Figure5 -58.
Figure5-58 AC Power Cable IEC 309 Plug (International)
Complete the following steps to connect a North American AC power cord to the switch:
Step1 Insert the female connector into the AC receptacle on the AC power supply tray.
Step2 Twist the plug to the right to secure it.
Step3 Insert the other end of the power cable into the wall outlet.
Step4 Repeat Step 1 through Step 3 to connect the other AC cable to the remaining AC power supply tray.
Complete the following steps to connect an international AC power cable to the switch:
Step1 Insert the female connector into the AC power supply tray receptacle, as shown in Figure5-59.
44147x
To power supply To AC outlet
75422
To AC outlet