Introduction
Editing Features
SPS208G/SPS224G4/SPS2024 Command Line Interface Reference Guide 30
1
Command Completion
If the command entered is incomplete, invalid or has missing or invalid parameters,
then the appropriate error message is displayed. This assists in entering the
correct command. By pressing Tab after an incomplete command is entered, the
system will attempt to identify and complete the command. If the characters
already entered are not enough for the system to identify a single matching
command, press ? to display the available commands matching the characters
already entered.
Nomenclature
Within the CLI, Ethernet ports are denoted as follows:
The ports may be described on an individual basis or within a range. Use format
port number-port number to specify a set of consecutive ports and port number,
port number to indicate a set of non-consecutive ports. For example, g1- 3 stands
for Gigabit Ethernet ports 1, 2, and 3, and g1,5 stands for Gigabit Ethernet ports 1
and 5.
Switch 10/100 Ethernet
ports
Gigabit Ethernet
ports
SPS208G e1 through e8 g1 through g2
SPS224G4 e1 through e24 g1 through g4
SPS2024 n/a g1 through g24