Crane Merchandising Systems 678, 670 I. Location Preparation, Initial Setup, Power, Requirements

Models: 678 670

1 141
Download 141 pages 50.45 Kb
Page 19
Image 19
HOT DRINK SETUP/PROGRAMMING GUIDE

HOT DRINK SETUP/PROGRAMMING GUIDE

INITIAL SETUP

I. LOCATION PREPARATION

After your machine is unpacked and placed near its permanent location, you need to make sure you have the proper electrical and water service.

ELECTRICAL POWER REQUIREMENTS

This merchandiser needs electrical power as shown in the following table.

NOTE

Each merchandiser should have its own electrical circuit.

 

Power
Requirements

 

Country

Volts

 

Frequency (Hz)

Current (Amp

 

 

 

 

 

Canada

115

 

60

15

 

 

 

 

 

France

230

 

50

10

 

 

 

 

 

Germany

230

 

50

10

 

 

 

 

 

United Kingdom

230

 

50

10

 

 

 

 

 

United States

115

 

60

15

 

 

 

 

 

1. Check the Power Outlet

This merchandiser is supplied with a service cord for the country of use and is termi- nated in a grounding type plug. The wall receptacle used for this merchandiser must be properly polarized, grounded, and of the correct voltage. Operating the merchandiser from a source of low voltage will VOID YOUR WARRANTY. Each merchandiser should have its own electrical circuit and that circuit should be protected with a circuit breaker or fuse conforming to local regulations.

Voltage Check - Place the leads of a voltmeter across the LINE (LIVE) and NEUTRAL terminals of the wall receptacle. The voltmeter should indicate 110-130 volts ac for 120 volt, 60 Hz locations, or 220-240 volts ac for 230 volt, 50 Hz locations.

Polarity Check - Place the leads of a voltmeter across the LINE (LIVE) and GROUND terminals of the wall receptacle. The voltmeter should indicate 110-130 volts ac for 120 volt, 60 Hz locations, or 220-240 volts ac for 230 volt, 50 Hz locations.

Noise Potential Check - Place the leads of a voltmeter across the NEUTRAL and GROUND terminals of the wall receptacle. The voltmeter should indicate 0 volts ac. A measurement greater than 1.5-2.0 volts ac could result in problems for the merchandiser's electronic circuitry caused by electrical noise.

Any deviation from these requirements could result in unreliable performance from your merchandiser.