screen. NOTE: This is the actual machine type

 

HOT DRINK SETUP/PROGRAMMING GUIDE

KEYSWITCH

The keyswitch input is active and configured as

 

an inhibit.

 

MACH.TYPE 0

Machine type error displays machine type

 

screen. NOTE: This is the actual machine type

 

screen. You may enter the correct machine type

 

number directly on this screen without further

 

action.

 

D+J+WXYZ

Configuration error; displays the machine

 

configuration screen. NOTE: this is the actual

 

config screen. You may enter the correct config

 

number directly on this screen without further

 

action.(Verify cup size and product times in the

 

product configuration

screen).

TANK ERR

Tank failed to fill or refill.

 

RING 1, 2

The cup ring is jammed.

 

MTR 1A1B2X

Cup turrets are jammed.

 

NO CUPS 1, 2

Out of cups.

 

BREW JAM

The brewer is jammed.

 

WASTE PAIL

The waste pail is full.

 

LOW WATER

The water level in the tank is low.

COLD WATER

Water in the tank is too cold to vend.

NO SENSOR

Temperature sensor failed or missing.

NO FLOAT

Float sensor failed or missing.

 

WHIP 1 2 3 4 5

Whipper motor failure (motor 1, 2, 3, 4,

 

5)

 

DOOR JAM

The automatic delivery door is jammed.

NO MECH

Coin mech not detected - machine will

 

not operate if configured for coin mech

6700001

Page - 95

November, 2002

Page 113
Image 113