Crane Merchandising Systems 678, 670 Set Up Low Temperature Dispensing, Set Up Low Power Settings

Models: 678 670

1 141
Download 141 pages 50.45 Kb
Page 63
Image 63
SET UP LOW TEMPERATURE DISPENSING

HOT DRINK SETUP/PROGRAMMING GUIDE

SET UP LOW POWER SETTINGSSET UP LOW TEMPERATURE DISPENSING

1. Press

then press

until the screen displays either

LTDIS OFF. This causes the machine to operate the same as the previ- ous Hot Drink Center. For example, with a setpoint temperature of 202º F the machine will inhibit vending when the water tank temperature reaches 182º F.

-or-

LTDIS ON. Allows vending to a water tank temperature of 140º F.

2. Press

to change between ON and OFF.

3. Continue.

(Continued)SET UP LOW POWER SETTINGS

Low power settings allow for the water tank to be set to a lower temperature at up to 4 different dates and times. For example, you want to lower the tank temperature to 160º F overnight on Mondays through Fridays. The machine tank temperature setpoint will be changed to 160º F at 6:00 pm and maintained at that temperature until 5:00 am on the following morning when the setpoint is returned to 202º F. Please keep in mind that at 5:00, the machine will just begin to increase to the 202º F setpoint temperature. It is up to you to determine how long that will take and to allow enough time for the tank to be at its proper temperature when the machine will be used. Typically, one hour is adequate to return to the normal operating temperature.

NOTE:

The machine OUT OF SERVICE condition during the low power interval will be determined by how you have set the LTDIS configuration.

(Continued)

6700001

Page - 45

November, 2002

Page 63
Image 63
Crane Merchandising Systems 678, 670 manual Set Up Low Temperature Dispensing, Set Up Low Power Settings, Continued