Table 1-7. LCD Status Messages (continued)

Code

Text

Causes

Corrective Actions

 

 

 

 

E1211

ROMB Batt

RAID battery is either missing,

Reseat the RAID battery

 

 

bad, or unable to recharge due to

connector. See "RAID Battery" on

 

 

thermal issues.

page 60, and "Troubleshooting

 

 

 

System Cooling Problems" on

 

 

 

page 101.

 

 

 

 

E1229

CPU # VCORE

Processor # VCORE voltage

See "Getting Help" on page 125.

 

 

regulator has failed.

 

E1310

RPM Fan ##

RPM of specified cooling fan is

See "Troubleshooting System

 

 

out of acceptable operating range.

Cooling Problems" on page 101.

E1311

RPM Fan Mod #x

RPM of fan x in the # module is

See "Troubleshooting System

 

 

out of acceptable operating range.

Cooling Problems" on page 101.

E1313

Fan Redundancy

The system is no longer fan-

Check control panel LCD for

 

 

redundant. Another fan failure will

additional scrolling messages. See

 

 

put the system at risk of over-

"Troubleshooting System Cooling

 

 

heating.

Problems" on page 101.

 

 

 

 

E1410

CPU # IERR

Specified microprocessor is

See your system’s "Information

 

 

reporting an internal error.

Update Tech Sheet" located on

 

 

 

support.dell.com for the most

 

 

 

current system information. If the

 

 

 

problem persists, see "Getting

 

 

 

Help" on page 125.

E1414 CPU # Thermtrip Specified microprocessor is out of acceptable temperature range and has halted operation.

See "Troubleshooting System Cooling Problems" on page 101. If the problem persists, ensure that the microprocessor heat sinks are properly installed. See "Troubleshooting the Microprocessors" on page 108. NOTE: The LCD continues to display this message until the system’s power cord is disconnected and reconnected to the AC power source, or the SEL is cleared using either Server Assistant or the BMC Management Utility. See the Dell OpenManage Baseboard Management Controller User’s Guide for information about these utilities.

18

About Your System

Page 18
Image 18
Dell 1950 owner manual CPU # Vcore