Code | Text | Causes | Corrective Actions |
|
|
|
|
E1211 | ROMB Batt | RAID battery is either missing, | Reseat the RAID battery |
|
| bad, or unable to recharge due to | connector. See "RAID Battery" on |
|
| thermal issues. | page 60, and "Troubleshooting |
|
|
| System Cooling Problems" on |
|
|
| page 101. |
|
|
|
|
E1229 | CPU # VCORE | Processor # VCORE voltage | See "Getting Help" on page 125. |
|
| regulator has failed. |
|
E1310 | RPM Fan ## | RPM of specified cooling fan is | See "Troubleshooting System |
|
| out of acceptable operating range. | Cooling Problems" on page 101. |
E1311 | RPM Fan Mod #x | RPM of fan x in the # module is | See "Troubleshooting System |
|
| out of acceptable operating range. | Cooling Problems" on page 101. |
E1313 | Fan Redundancy | The system is no longer fan- | Check control panel LCD for |
|
| redundant. Another fan failure will | additional scrolling messages. See |
|
| put the system at risk of over- | "Troubleshooting System Cooling |
|
| heating. | Problems" on page 101. |
|
|
|
|
E1410 | CPU # IERR | Specified microprocessor is | See your system’s "Information |
|
| reporting an internal error. | Update Tech Sheet" located on |
|
|
| support.dell.com for the most |
|
|
| current system information. If the |
|
|
| problem persists, see "Getting |
|
|
| Help" on page 125. |
E1414 CPU # Thermtrip Specified microprocessor is out of acceptable temperature range and has halted operation.
See "Troubleshooting System Cooling Problems" on page 101. If the problem persists, ensure that the microprocessor heat sinks are properly installed. See "Troubleshooting the Microprocessors" on page 108. NOTE: The LCD continues to display this message until the system’s power cord is disconnected and reconnected to the AC power source, or the SEL is cleared using either Server Assistant or the BMC Management Utility. See the Dell OpenManage Baseboard Management Controller User’s Guide for information about these utilities.
18