About Your System 23
E2111 SBE Log Disable
Crd # DIMM ## The system BIOS has disabled
memory single-bit error (SBE)
logging, and will not resume
logging further SBEs until the
system is rebooted. "##" represents
the DIMM implicated by the
BIOS. If no memory riser card is
present, the "Crd #" string is left
out of the message.
See "Troubleshooting System
Memory" on page 102.
E2112 Mem Spare Crd #
DIMM ## The system BIOS has spared the
memory because it has determin ed
that the memory had too many
errors. "## & ##" represents the
DIMM pair implicated by the
BIOS. If no memory card is
present, the "Crd #" string is left
out of the message.
See "Troubleshooting System
Memory" on page 102.
E2113 Mem Mirror Crd #
DIMM ## & ## The system BIOS has disabled
memory mirroring because it has
determined that one half of the
mirror has had too many errors.
"## & ##" represents the DIMM
pair implicated by the BIOS. If no
memory card is present, the "Crd
#" string is left out of the message.
See "Troubleshooting System
Memory" on page 102.
E2118 Fatal NB Mem CRC One of the connection s in the FBD
memory subsystem link on the
Northbound side has failed.
See "Troubleshooting System
Memory" on page 102.
E2119 Fatal SB Mem CRC One of the connection s in the FBD
memory subsystem link on the
Southbound side has failed.
See "Troubleshooting System
Memory" on page 102.
I1910 Intrusion System cover has been removed. Information only.
I1911 >3 ERRs Chk Log LCD overflow message.
A maximum of three error
messages can display sequentially
on the LCD. The fourth message
displays as the standard overflow
message.
Check the SEL for details on the
events.
Table 1-7. LCD Status Messages (continued)
Code Text Causes Corrective Actions