Table
Code | Text | Causes | Corrective Actions |
|
|
|
|
E2111 | SBE Log Disable | The system BIOS has disabled | See "Troubleshooting System |
| Crd # DIMM ## | memory | Memory" on page 102. |
|
| logging, and will not resume |
|
|
| logging further SBEs until the |
|
|
| system is rebooted. "##" represents |
|
|
| the DIMM implicated by the |
|
|
| BIOS. If no memory riser card is |
|
|
| present, the "Crd #" string is left |
|
|
| out of the message. |
|
|
|
|
|
E2112 | Mem Spare Crd # | The system BIOS has spared the | See "Troubleshooting System |
| DIMM ## | memory because it has determined | Memory" on page 102. |
|
| that the memory had too many |
|
|
| errors. "## & ##" represents the |
|
|
| DIMM pair implicated by the |
|
|
| BIOS. If no memory card is |
|
|
| present, the "Crd #" string is left |
|
|
| out of the message. |
|
|
|
|
|
E2113 | Mem Mirror Crd # | The system BIOS has disabled | See "Troubleshooting System |
| DIMM ## & ## | memory mirroring because it has | Memory" on page 102. |
|
| determined that one half of the |
|
|
| mirror has had too many errors. |
|
|
| "## & ##" represents the DIMM |
|
|
| pair implicated by the BIOS. If no |
|
|
| memory card is present, the "Crd |
|
|
| #" string is left out of the message. |
|
|
|
|
|
E2118 | Fatal NB Mem CRC | One of the connections in the FBD | See "Troubleshooting System |
|
| memory subsystem link on the | Memory" on page 102. |
|
| Northbound side has failed. |
|
|
|
|
|
E2119 | Fatal SB Mem CRC | One of the connections in the FBD | See "Troubleshooting System |
|
| memory subsystem link on the | Memory" on page 102. |
|
| Southbound side has failed. |
|
|
|
|
|
I1910 | Intrusion | System cover has been removed. | Information only. |
I1911 | >3 ERRs Chk Log | LCD overflow message. | Check the SEL for details on the |
|
| A maximum of three error | events. |
|
|
|
messages can display sequentially on the LCD. The fourth message displays as the standard overflow message.