Figure 3-6. Memory Cooling Shroud

12

 

 

 

 

 

3

 

 

 

4

 

 

1

memory cooling shroud

2

memory shroud release tab

3

memory modules (8)

4

system processors (2)

 

 

 

 

Replacing the Memory Cooling Shroud

1To install the memory cooling shroud, align the shroud directly over the memory modules and the processors.

2Using the interior system board cooling shroud as a guide, slowly lower the shroud straight down onto the system, directly over the processors and memory modules.

3Gently press around the periphery of the shroud until it engages with the external tabs and snaps into place.

Power Supplies

Your system supports one or two power supplies rated at an output of 670 W. If only one power supply is installed, it must be installed in the left power supply bay (bay 1). If two power supplies are installed, the second power supply serves as a redundant, hot-plug power source.

NOTICE: In a non-redundant configuration, the power supply blank must be installed in the unoccupied power supply bay to ensure proper system cooling. See "Installing the Power Supply Blank" on page 56.

Installing System Components

53

Page 53
Image 53
Dell 1950 owner manual Power Supplies