Table 1-7. LCD Status Messages (continued)

Code

Text

Causes

Corrective Actions

 

 

 

 

E1811

HDD ## Rbld Abrt

The specified hard drive has

See "Troubleshooting a Hard

 

 

experienced a rebuild abort.

Drive" on page 104. If the problem

 

 

 

persists, see your RAID

 

 

 

documentation.

 

 

 

 

E1812

HDD ## Removed

The specified hard drive has been

Information only.

 

 

removed from the system.

 

E1913

CPU & Firmware

The BMC firmware does not

 

Mismatch

support the CPU.

Update to the latest BMC firmware. See the BMC User’s Guide for more information on setup and use of BMC.

E1A14

SAS Cable A

SAS cable A is missing or bad.

Reseat the cable. If the problem

 

 

 

persists, replace the cable. See

 

 

 

"SAS Controller Daughter Card"

 

 

 

on page 56.

E1A15

SAS Cable B

SAS cable B is missing or bad.

Reseat the cable. If the problem persists, replace the cable. See "SAS Controller Daughter Card" on page 56.

E1A17

Pwr Cable FB

Flex bay power cable is missing or

 

 

bad.

Reseat the cable. If the problem persists, replace the cable. See "SAS Controller Daughter Card" on page 56.

E1A18

PDB Ctrl Cable

Flex bay control signals cable is

 

 

missing or bad.

Reseat the cable. If the problem persists, replace the cable. See "SAS Controller Daughter Card" on page 56.

E2010

No Memory

No memory is installed in the

Install memory. See "Installing

 

 

system.

Memory Modules" on page 65.

E2011

Mem Config Err

Memory detected, but is not

See "Troubleshooting System

 

 

configurable. Error detected

Memory" on page 102.

 

 

during memory configuration.

 

 

 

 

 

E2012

Unusable Memory

Memory is configured, but not

See "Troubleshooting System

 

 

usable. Memory subsystem failure.

Memory" on page 102.

E2013

Shadow BIOS Fail

The system BIOS failed to copy its

See "Troubleshooting System

 

 

flash image into memory.

Memory" on page 102.

E2014

CMOS Fail

CMOS failure. CMOS RAM not

See "Getting Help" on page 125.

 

 

functioning properly.

 

E2015

DMA Controller

DMA controller failure.

See "Getting Help" on page 125.

About Your System

21

Page 21
Image 21
Dell 1950 owner manual Support the CPU