Table
Code | Text | Causes | Corrective Actions |
|
|
|
|
E2016 | Int Controller | Interrupt controller failure. | See "Getting Help" on page 125. |
E2017 | Timer Fail | Timer refresh failure. | See "Getting Help" on page 125. |
E2018 | Prog Timer | Programmable interval timer error. | See "Getting Help" on page 125. |
E2019 | Parity Error | Parity error. | See "Getting Help" on page 125. |
E201A | SIO Err | SIO failure. | See "Getting Help" on page 125. |
E201B | Kybd Controller | Keyboard controller failure. | See "Getting Help" on page 125. |
E201C | SMI Init | System management interrupt | See "Getting Help" on page 125. |
|
| (SMI) initialization failure. |
|
E201D | Shutdown Test | BIOS shutdown test failure. | See "Getting Help" on page 125. |
E201E | POST Mem Test | BIOS POST memory test failure. | See "Troubleshooting System |
|
|
| Memory" on page 102. If the |
problem persists, see "Getting Help" on page 125.
E201F | DRAC Config | Dell remote access controller |
|
| (DRAC) configuration failure. |
Check for specific error messages.
Ensure that DRAC cables and connectors are properly seated. If the problem persists, see your DRAC documentation.
E2020 | CPU Config | CPU configuration failure. | Check for specific error messages. |
E2021 | Memory | Incorrect memory configuration. | Check for specific error messages. |
| Population | Memory population order | See "Troubleshooting System |
|
| incorrect. | Memory" on page 102. |
E2022 | POST Fail | General failure after video. | Check for specific error messages. |
E2110 | MBE Crd # DIMM ## | One of the DIMMs in the set | See "Troubleshooting System |
| & ## | implicated by "## & ##" has had a | Memory" on page 102. |
|
| memory |
|
|
| no memory card is present, the |
|
|
| "Crd #" string is left out of the |
|
|
| message. |
|
22