0x2804 Freeze object

This object is used to configure the freeze function that can be used within the Homing mode profile. Table 7.55 Freeze object on page 53 specifies the object description.

Table 7.55 Freeze object

0x2804

Freeze object

 

 

Sub-index 0

 

 

 

 

Access: RO

 

Range: N/A

Size: Unigned 8

Unit: N/A

 

 

 

 

 

Default: 2

 

 

 

 

Description: The number of the last sub-index in this object.

 

 

 

 

 

 

Sub-index 1

 

 

 

 

 

 

 

 

 

Access: RW

 

Range: 0 to 1

Size: Unsigned 8

Unit: N/A

Default: 0

Description: Route the option freeze onto the drive. Setting a value of 1 here will route the option digital input 0 onto the drive freeze line.

Sub-index 2

Access: RW

Range: 0 to 1

Size: Unsigned 8

Unit: N/A

Default: 0

 

 

 

Description: Option to drive freeze invert. Setting a value of 1 will invert the freeze signal routed onto the drive from the option input 0 (if 0x2804, sub-index 1 is set to 1). This value will be read only on a transition from 0 to 1 in sub-index 1.

0x607C Home offset

This object indicates the configured difference between the zero position for the application and the machine home position (found during homing). During homing the machine home position is found and once the homing is completed the zero position is offset from the home position by adding the home offset to the home position. All subsequent absolute moves shall be taken relative to this new zero position. This is illustrated in Figure 7-11Home offset definition on page 53. The value of this object shall be given in user-defined position units. Negative values indicate the opposite direction.

Figure 7-11 Home offset definition

Table 7.56 Home offset

0x607C

Home offset

 

 

Access: RW

 

Range: -32768 to

Size: Signed 32

Unit: User-defined

 

+32767

position units

 

 

 

Default:

0

 

 

 

 

 

 

 

Description:

Homing offset value.

 

 

Information

Safety

 

Introduction

 

 

Installation

Mechanical

 

 

Installation

Electrical

 

Getting Started

 

Protocols

 

 

support

Drive profile (DSP-402)

features

Advanced

 

Diagnostics

 

 

Reference

Quick

 

 

Terms

Glossary

 

Of

 

Index

 

 

SM-EtherCAT User Guide

53

Issue Number: 2

www.controltechniques.com

Page 53
Image 53
Emerson 0471-0128-02 manual 0x2804 Freeze object, 0x607C Home offset