7.3.30x605B Shutdown_option_code

This object is used to control what action is performed if there is a transition from the Operation Enabled state to the Ready To Switch On state.

Table 7.11 Shutdown_option_code

0x605B

Shutdown_option_code

 

 

Access: RW

 

Range: 0 to 1

 

Size: Unsigned 16

Unit: N/A

 

 

 

 

 

 

Default:

N/A

 

 

 

 

Description:

Used to control what action is performed if there is a transition from the Operation Enabled

 

state to the Ready To Switch On state.

 

 

 

 

 

 

 

 

Table 7.12 Shutdown_option_code values

Value

Definition

0

Disable drive function (switch-off the drive power stage)

1Slow down with slow down ramp; disable the drive function

7.3.40x605C Disable_operation_option_code

Disable drive function (switch-off the drive power stage).

This object is used to control what action is performed if there is a transition from the ‘Operation Enabled’ state to the ‘Switched On’ state.

Table 7.13 Disabled_operation_option_code

0x605C

Disable_operation_option_code

Access: RW

 

Range: 0 to 1

Size: Unsigned 16

Unit: N/A

 

 

 

 

 

Default:

N/A

 

 

Description: This object is used to control what action is performed if there is a transition from the Operation Enabled state to the Switched On state.

Table 7.14 Disable_operation_option_code values

Value

Definition

0Disable drive function (switch-off the drive power stage)

1Slow down with slow down ramp; disable the drive function

7.3.50x605E Fault_reaction_option_code

This object is used to control what action is performed when a fault is detected. This object is ignored if the drive is tripped.

Table 7.15 Fault_reaction_option_code

0x605E

Fault_reaction_option_code

 

 

Access: RW

 

Range: 0 to 2

Size: Unsigned 16

Unit: N/A

Default:

N/A

 

 

 

 

 

Description:

This object is used to control what action is performed when a fault is detected.

Table 7.16 Fault_reaction_option_code values

Value

Definition

0

Disable drive function, motor is free to rotate

1

Slow down on slow down ramp

 

 

2

Slow down on quick stop ramp