Emerson Process Management 2051 manual Rosemount, Reference Manual, 00809-0200-4101,Rev AA July

Models: 2051

1 152
Download 152 pages 41.56 Kb
Page 134
Image 134
Manual background

Rosemount 2051

Reference Manual

00809-0200-4101, Rev AA July 2008

 

Index

 

Parameter

Number

Description

 

 

 

SENSOR_TYPE

20

Type of sensor connected with the transducer block.

 

 

Valid sensor types are the following:

 

 

117 = Capacitance

 

 

124 = Strain Gauge

ST_REV

01

The revision level of the static data associated with the function block.

 

 

 

STRATEGY

03

The strategy field can be used to identify grouping of blocks.

TAG_DESC

02

The user description of the intended application of the block.

 

 

 

TB_DETAILED_STATUS

31

Indicates the state of the transmitter. The parameter contains specific codes relating to

 

 

the transducer block and the pressure sensor specifically.

TRANSDUCER_DIRECTORY

09

Directory that specifies the number and starting indices of the transducers in the

 

 

transducer block.

 

 

 

TRANSDUCER_TYPE

10

Identifies the transducer that follows.

 

 

100 = Standard pressure with calibration

UPDATE_EVT

07

This alert is generated by any change to the static data.

 

 

 

XD_ERROR

11

Provides additional error codes related to transducer blocks.

 

 

 

Block/Transducer Errors The following conditions are reported in the BLOCK_ERR and XD_ERROR parameters. Conditions in bold type are available. Conditions in italics are inactive for the Transducer block and are given here only for your reference.

Condition

 

Number

Condition Name and Description

0Other

1Block Configuration Error

2Link Configuration Error

3Simulate Active

4Local Override

5Device Fault State Set

6Device Needs Maintenance Soon

7Input failure/process variable has bad status

8Output Failure

9Memory Failure

10Lost Static Data

11Lost NV Data

12Readback Check Failed

13Device Needs Maintenance Now

14Power Up: The device was just powered-up.

15Out of Service: The actual mode is out of service.

17

General Error: A general error that cannot be specified below occurred

 

 

20

Electronics Failure: An electrical component failed.

 

 

22I/O Failure: An I/O failure occurred.

23Data Integrity Error: Data stored in the device is no longer valid due to a non-volatile memory checksum failure, a data verify after write failure, etc.

25Algorithm Error: The algorithm used in the transducer block produced an error due to overflow, data reasonableness failure, etc.

C-4

Page 134
Image 134
Emerson Process Management 2051 manual Rosemount, Reference Manual, 00809-0200-4101,Rev AA July