Manual background

Rosemount 2051

Reference Manual

00809-0200-4101, Rev AA July 2008

Code

Process Fill-High Pressure Side

Temperature Limits

 

 

 

 

 

 

 

 

 

 

A

Syltherm® XLT

 

-100 to 300 °F (-73 to 135 °C)

 

 

 

 

 

 

 

 

 

 

C

D.C. Silicone 704

 

60 to 400 °F (15 to 205 °C)

 

 

D

D.C. Silicone 200

 

-40 to 400 °F (-40 to 205 °C)

 

 

 

 

 

 

 

 

 

 

H

Inert (Halocarbon)

 

-50 to 350 °F (-45 to 177 °C)

 

 

G

Glycerin and Water

 

0 to 200 °F (-17 to 93 °C)

 

 

 

 

 

 

 

 

 

 

N

Neobee® M-20

 

0 to 400 °F (-17 to 205 °C)

 

 

P

Propylene Glycol and Water

 

0 to 200 °F (-17 to 93 °C)

 

 

 

 

 

 

 

 

 

 

Code

Low Pressure Side

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Configuration

Flange Adapter

Diaphragm Material

Sensor Fill Fluid

 

 

 

 

 

 

 

 

11

Gage

SST

316L SST

Silicone

 

21

Differential

SST

316L SST

Silicone

 

 

 

 

 

 

 

22

Differential (SST Valve Seat)

SST

Alloy C-276

Silicone

 

2A

Differential

SST

316L SST

Inert (Halocarbon)

 

 

 

 

 

 

 

2B

Differential (SST Valve Seat)

SST

Alloy C-276

Inert (Halocarbon)

 

31

Remote Seal

SST

316L SST

Silicone

 

 

 

 

 

 

 

 

Code

O-ring

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AGlass-filled PTFE

Code

Housing Material

Conduit Entry Size

 

 

 

A

Polyurethane-covered Aluminum

½–14 NPT

 

 

 

B

Polyurethane-covered Aluminum

M20 × 1.5 (CM20)

D

Polyurethane-covered Aluminum

 

 

 

J

SST (consult factory for availability)

½–14 NPT

K

SST (consult factory for availability)

M20 × 1.5 (CM20)

 

 

 

M

SST (consult factory for availability)

Code

Options

 

 

 

Diaphragm Seal Assembly

 

 

 

 

S1(1)

Assemble to one Rosemount 1199 diaphragm seal

 

Product Certifications

 

 

 

 

E1(2)

ATEX Flameproof

 

E2(2)

INMETRO Flameproof (consult factory for availability)

 

E3(2)

China Flameproof (consult factory for availability)

 

E4(2)

TIIS Flameproof (consult factory for availability)

 

E5

FM Explosion-proof, Dust Ignition-proof

 

E6

CSA Explosion-proof, Dust Ignition-proof, Division 2

 

 

 

 

E7

IECEx Flameproof

 

EP(2)

Korea (KOSHA) Flameproof Approval (consult factory for availability)

EW(2)

India (CCOE) Flameproof Approval (consult factory for availability)

EM(2)

GOST Explosion-proof(consult factory for availability)

 

I1

ATEX Intrinsic Safety

 

I2(2)

INMETRO Intrinsic Safety (consult factory for availability)

 

I3(2)

China Intrinsic Safety (consult factory for availability)

 

I4(2)

TIIS Intrinsic Safety (consult factory for availability)

 

I5

FM Intrinsically Safe, Division 2

 

I6

CSA Intrinsically Safe

 

 

 

 

I7(2)

IECEx Intrinsic Safety

 

IA(3)

ATEX FISCO Intrinsic Safety

 

IB(3)

INMETRO FISCO Intrinsic Safety (consult factory for availability)

ID(3)

TIIS FISCO Intrinsic Safety (consult factory for availability)

 

IE(3)

FM FISCO Intrinsically Safe

 

IF(3)

CSA FISCO Intrinsically Safe

 

IG(3)

IECEx FISCO Intrinsically Safe

 

IP(2)

Korea (KOSHA) Instrinsic Safety (consult factory for availability)

IM(2)

GOST Intrinsically Safe (consult factory for availability)

 

A-20

Page 92
Image 92
Emerson Process Management 2051 manual Rosemount, Reference Manual, Syltherm XLT