Emerson Process Management 2051 manual Rosemount, Reference Manual

Models: 2051

1 152
Download 152 pages 41.56 Kb
Page 85
Image 85
Alternate Process Connection: Flange(2)

Reference Manual

00809-0200-4101, Rev AA July 2008

Rosemount 2051

Code

Options

CD

CG

 

 

 

Alternate Process Connection: Flange(2)

 

 

H2

Traditional Flange, 316 SST, SST Drain/Vent

H3(1)

Traditional Flange, Cast C-276, Alloy C-276 Drain/Vent

H7(1)

Traditional Flange, 316 SST, Alloy C-276 Drain/Vent

HJ

DIN Compliant Traditional Flange, SST, 7/16 in. Adapter/Manifold Bolting

 

 

 

 

HK(3)

DIN Compliant Traditional Flange, SST, 10 mm Adapter/Manifold Bolting

HL

DIN Compliant Traditional Flange, SST, 12mm Adapter/Manifold Bolting

 

 

 

 

FA

Level Flange, SST, 2 in., ANSI Class 150, Vertical Mount

FB

Level Flange, SST, 2 in., ANSI Class 300, Vertical Mount

 

 

 

 

FC

Level Flange, SST, 3 in., ANSI Class 150, Vertical Mount

FD

Level Flange, SST, 3 in., ANSI Class 300, Vertical Mount

 

 

 

 

FP

DIN Level Flange, SST, DN 50, PN 40, Vertical Mount

FQ

DIN Level Flange, SST, DN 80, PN 40, Vertical Mount

 

 

 

Alternate Process Connection: Manifold(2)(4)

 

 

S5

Assemble to Rosemount 305 Integral Manifold

 

 

 

 

S6

Assemble to Rosemount 304 Manifold or Connection System

 

 

 

 

Alternate Process Connection: Primary Element(2)(4)

S4(5)

Assemble to Rosemount Primary Element

S3

Assemble to Rosemount 405 Primary Element

Diaphragm Seal Assemblies(4)

S1(6)

Assemble to one Rosemount 1199 diaphragm seal

S2(7)

Assemble to two Rosemount 1199 diaphragm seals

Mounting Brackets

B1(8)

Traditional Flange Bracket for 2-in. Pipe Mounting, CS Bolts

B2(8)

Traditional Flange Bracket for Panel Mounting, CS Bolts

B3(8)

Traditional Flange Flat Bracket for 2-in. Pipe Mounting, CS Bolts

B4(9)

Coplanar Flange Bracket for 2-in. Pipe or Panel Mounting, all SST

B7(8)

B1 Bracket with Series 300 SST Bolts

B8(8)

B2 Bracket with Series 300 SST Bolts

B9(8)

B3 Bracket with Series 300 SST Bolts

BA(8)

SST B1 Bracket with Series 300 SST Bolts

BC(8)

SST B3 Bracket with Series 300 SST Bolts

Product Certifications

E1(10)

ATEX Flameproof

E2(10)

INMETRO Flameproof (consult factory for availability)

E3(10)

China Flameproof (consult factory for availability)

E4(10)

TIIS Flameproof (consult factory for availability)

E5

FM Explosion-proof, Dust Ignition-proof

E6

CSA Explosion-proof, Dust Ignition-proof, Division 2

E7

IECEx Flameproof

EP(10)

Korea (KOSHA) Flameproof Approval (consult factory for availability)

EW(10)

India (CCOE) Flameproof Approval (consult factory for availability)

EM(10)

GOST Explosion-proof(consult factory for availability)

I1

ATEX Intrinsic Safety

I2(10)

INMETRO Intrinsic Safety (consult factory for availability)

I3(10)

China Intrinsic Safety (consult factory for availability)

I4(10)

TIIS Intrinsic Safety (consult factory for availability)

I5

FM Intrinsically Safe, Division 2

I6

CSA Intrinsically Safe

I7(10)

IECEx Intrinsic Safety

IA(11)

ATEX FISCO Intrinsic Safety

IB(11)

INMETRO FISCO Intrinsic Safety (consult factory for availability)

ID(11)

TIIS FISCO Intrinsic Safety (consult factory for availability)

IE(11)

FM FISCO Intrinsically Safe

A-13