Emerson Process Management 2051 manual Rosemount, Reference Manual, Flange_Mtl

Models: 2051

1 152
Download 152 pages 41.56 Kb
Page 138
Image 138
FLANGE_MTL

Rosemount 2051

Reference Manual

00809-0200-4101, Rev AA July 2008

 

Index

 

 

Parameter

Number

Description

 

 

 

FLANGE_MTL

69

Type of material of the flange. See flange material codes.

 

 

0 = Carbon Steel

 

 

2 = 316 Stainless Steel

 

 

3 = Hastelloy C

 

 

4 = Monel

 

 

24

= Kynar

 

 

252 = "Unknown"

 

 

253 = "Special"

FLANGE_TYPE

68

Type of flange that is attached to the device.

 

 

12

= Conventional (Traditional)

 

 

13

= Coplanar

 

 

14

= Remote Seal

 

 

15

= Level; 3 in. 150 lbs.

 

 

16

= Level; 4 in. 150 lbs.

 

 

17

= Level; 3 in. 300 lbs.

 

 

18

= Level; 4 in. 300 lbs.

 

 

19

= Level; DN 80, PN 40

 

 

20

= Level; DN 100, PN 40

 

 

21

= Level; DN 100, PN 10/16

 

 

22

= Level; 2 in. 150 lbs.

 

 

23

= Level; 2 in. 300 lbs.

 

 

24

= Level; DN 50, PN 6

 

 

25

= Level; DN 50, PN 40

 

 

252 = "Unknown"

 

 

253 = "Special"

 

 

 

FREE_TIME

25

Percent of the block processing time that is free to process additional blocks.

FREE_SPACE

24

Percent of memory available for further configuration. Zero in a preconfigured device.

 

 

 

GRANT_DENY

14

Options for controlling access of host computers and local control panels to operating,

 

 

tuning, and alarm parameters of the block. Not used by device.

HARD_TYPES

15

The types of hardware available as channel numbers.

 

 

 

hardware_rev

52

Hardware revision of the hardware that has the resource block in it.

LIM_NOTIFY

32

Maximum number of unconfirmed alert notify messages allowed.

 

 

 

MANUFAC_ID

10

Manufacturer identification number – used by an interface device to locate the DD file for

 

 

the resource.

MAX_NOTIFY

31

Maximum number of unconfirmed alert notify messages possible.

 

 

 

MEMORY_SIZE

22

Available configuration memory in the empty resource. To be checked before

 

 

attempting a download.

message_date

57

Date associated with the MESSAGE_TEXT parameter.

 

 

 

message_text

58

Used to indicate changes made by the user to the device's installation, configuration,

 

 

or calibration.

MIN_CYCLE_T

21

Time duration of the shortest cycle interval of which the resource is capable.

 

 

 

MODE_BLK

05

The actual, target, permitted, and normal modes of the block:

 

 

Target: The mode to “go to”

 

 

Actual: The mode the “block is currently in”

 

 

Permitted: Allowed modes that target may take on

 

 

Normal: Most common mode for actual

NV_CYCLE_T

23

Minimum time interval specified by the manufacturer for writing copies of NV parameters

 

 

to non-volitile memory. Zero means it will never be automativally copied. At the end of

 

 

NV_CYCLE_T, only those parameters which have changed need to be updated in

 

 

NVRAM.

 

 

 

O_RING_MTL

69

Type of material of the flange o-rings. See O-ring material codes.

 

 

10

= PTFE (Teflon TM)

 

 

11 = Viton

 

 

12

= Buna–N

 

 

13

= Ethyl–Prop

 

 

252 = "Unknown"

 

 

253 = "Special"

output_board_sn

53

Output board serial number.

C-8