FUNCTIONAL

Rosemount 2051

FUNCTIONAL

SPECIFICATIONS

Range and Sensor Limits

Range

 

 

Minimum Span

Upper (URL)

 

 

 

 

1

0.5 inH2O

25 inH2O

 

(1,2 mbar)

(62,3 mbar)

Reference Manual

00809-0200-4101, Rev AA

July 2008

2051CD, 2051CG, 2051L

Range and Sensor Limits

Lower (LRL)

2051C Differential

2051C Gage(1)

2051L Differential

2051L Gage(1)

–25 inH2O

–25 inH2O

N/A

N/A

(–62,1 mbar)

(–62,1 mbar)

 

 

2

2.5 inH2O

250 inH2O

–250 inH2O

–250 inH2O

–250 inH2O

–250 inH2O

 

(6,2 mbar)

(0,62 bar)

(–0,62 bar)

(–0,62 bar)

(–0,62 bar)

(–0,62 bar)

3

10 inH2O

1000 inH2O

-1000 inH2O

–393 inH2O

–1000 inH2O

–393 inH2O

 

(24,9 mbar)

(2,49 bar)

(-2,49 bar)

(–979 mbar)

(–2,49 bar)

(–979 mbar)

 

 

 

 

 

 

 

4

3 psi

300 psi

-300 psi

–14.2 psig

–300 psi

–14.2 psig

 

(0,207 bar)

(20,6 bar)

(-20,6 bar)

(–979 mbar)

(–20,7 bar)

(–979 mbar)

 

 

 

 

 

 

 

5

20 psi

2000 psi

 

(1,38 bar)

(137,9 bar)

(1) Assumes atmospheric pressure of 14.7 psig.

Range

 

Minimum

 

Span

 

 

1

0.3 psi

 

(20,6 mbar)

-2000 psi

–14.2 psig

N/A

N/A

(-137,9 bar)

(–979 mbar)

 

 

 

2051T

 

 

 

Range and Sensor Limits

 

Upper

 

Lower

Lower(1)

(URL)

 

(LRL) (Abs)

(LRL) (Gage)

30 psi

 

0 psia

–14.7 psig

(2,06 bar)

 

(0 bar)

(–1,01 bar)

2

1.5 psi

150 psi

0 psia

–14.7 psig

 

(0,103 bar)

(10,3 bar)

(0 bar)

(–1,01 bar)

3

8 psi

800 psi

0 psia

–14.7 psig

 

(0,55 bar)

(55,2 bar)

(0 bar)

(–1,01 bar)

 

 

 

 

 

4

40 psi

4000 psi

0 psia

–14.7 psig

 

(2,76 bar)

(275,8 bar)

(0 bar)

(–1,01 bar)

5

2000 psi

10000 psi

0 psia

–14.7 psig

 

(137,9 bar)

(689,4 bar)

(0 bar)

(–1,01 bar)

(1) Assumes atmospheric pressure of 14.7 psig.

Service

Liquid, gas, and vapor applications

Protocols

4–20 mA HART (Output Code A)

 

Output

 

Two-wire 4–20 mA, user-selectable for linear or square root output. Digital

 

process variable superimposed on 4–20 mA signal, available to any host

 

that conforms to the HART protocol.

 

Power Supply

 

External power supply required. Standard transmitter operates on 10.5 to

 

42.4 V dc with no load.

 

Turn-On Time

 

Performance within specifications less than 2.0 sections after power is

 

applied to the transmitter.

A-4