CSA FISCO Intrinsically Safe

Rosemount 2051

Reference Manual

00809-0200-4101, Rev AA July 2008

IF(11)

CSA FISCO Intrinsically Safe

IG(11)

IECEx FISCO Intrinsically Safe

IP(10)

Korea (KOSHA) Instrinsic Safety (consult factory for availability)

IM(10)

GOST Intrinsically Safe (consult factory for availability)

IW(10)

India (CCOE) Intrinsic Safety Approval (consult factory for availability)

K1(10)

ATEX Flameproof, Intrinsic Safety, Type n, Dust

K2(10)

INMETRO Flameproof, Intrinsic Safety, Type n (consult factory for availability)

K4(10)

TIIS Flameproof, Intrinsic Safety (consult factory for availability)

K5

FM Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2

 

 

 

 

K6

CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2

K7(10)

IECEx Flameproof, Intrinsic Safety, Type n

KA

ATEX and CSA Flameproof, Intrinsically Safe, Division 2

KB

FM and CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2

 

 

 

 

KC

FM and ATEX Explosion-proof, Intrinsically Safe, Division 2

KD(10)

FM, CSA, and ATEX Explosion-proof, Intrinsically Safe

N1(10)

ATEX Type n

 

N7(10)

IECEx Type n

 

ND

ATEX Dust

 

Bolting Configurations

 

 

 

 

 

L4

Austenitic 316 SST Bolts

L5

ASTM A 193, Grade B7M Bolts

 

 

 

 

L8

ASTM A 193 Class 2, Grade B8M Bolts

Digital Display

 

 

 

 

 

 

 

 

M5

LCD display

 

Special Configuration (Hardware)

 

 

 

 

 

 

D4(12)

Zero and Span Hardware Adjustments

DF(13)

1/2-14 NPT Flange Adapters

D9(14)

JIS Process Connection-RC 1/4 Flange with RC 1/2 Flange Adapter

V5(15)

External Ground Screw Assembly

Performance

 

 

 

P8(16)

0.065% accuracy and 5 year stability

Terminal Blocks

 

 

 

T1

Transient Protection Terminal Block

 

 

 

 

Special Configuration (Software)

 

 

 

C1(17)

Custom Software Configuration (Requires completed Configuration Data Sheet)

C4(17)(18)

Analog Output Levels Compliant with NAMUR Recommendation NE 43, Alarm High

CN(17)(18)

Analog Output Levels Compliant with NAMUR Recommendation NE 43 Alarm Low

Special Procedures

 

 

 

P1

Hydrostatic Testing with Certificate

 

 

 

 

P2(19)

Cleaning for Special Service

P9

4500 psig (310 bar) static pressure limit (Ranges 2-5 only)

 

 

 

 

P3(19)

Cleaning for <1 PPM Chlorine/Fluorine

Special Certifications

 

 

 

 

 

 

 

 

Q4

Calibration Certificate

 

Q8

Material Traceability Certification per EN 10204 3.1.B

 

 

 

 

QS(17)

Prior-use certificate of FMEDA data

Q16(20)

Surface finish certification for sanitary remote seals

QP

Calibration certification and tamper evident seal

QZ(20)

Remote Seal System Performance Calculation Report

Typical Model Number:

2051C D 2 A 2 2 A 1 A B4 M5

 

 

 

 

 

 

 

(1)Materials of Construction comply with recommendations per NACE MR0175/ISO 15156 for sour oil field production environments. Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.

(2)Requires 0 code in Materials of Construction for Alternate Process Connection.

(3)Not valid with optional code P9 for 4500psi Static Pressure.

(4)“Assemble-to” items are specified separately and require a completed model number.

(5)Process Flange limited to Coplanar (codes 2, 3, 5, 7, 8) or Traditional (H2, H3, H7).