Chapter 5 Configuration Menu
> 5.1 Resource Domain Management
ETERNUS DX400/DX8000 series ETERNUSmgr User Guide Settings/Maintenance
117 Copyright 2010 FUJITSU LIMITED
P2X0-0760-02ENZ0
3Change the Assigned Domain of the TPP, and click the [Set] button.
To set using [Set Range]
(1)Enter the first and last TPP numbers.
(2)Select the domain to assign the specified range of the TPPs from the list box.
(3)Click the [Execute] button.
(This screen is displayed when logged on the ETERNUS DX400/DX8000 series in
which the Resource Domains are registered using a Total Administrator account.)
If the [Execute] button is clicked in the following conditions, an error
screen appears.
Both or one of the "From: TPP No." or "To: TPP No." field is blank
Characters other than hexadecimal numbers are specified in the
"From: TPP No." or "To: TPP No." field
There are no TPPs where the Assigned Domain can be changed
in the range specified by the "From: TPP No." and "To: TPP No."
The Set Range setting is performed when the re is a t least o ne TPP
that satisfies all the conditions described in "Conditions in which a
Thin Provisioning Pool (TPP) can Assign to Domain/Change
Assigned Domain" (page 109).