Chapter 5 Configuration Menu
> 5.3 Thin Provisioning Management
ETERNUS DX400/DX8000 series ETERNUSmgr User Guide Settings/Maintenance
283 Copyright 2010 FUJITSU LIMITED
P2X0-0760-02ENZ0
3Click the [OK] button.
Thin Provisioning Volumes where the capacity will be expanded are displayed with a
yellow background.
When the [Thin Provisioning Volume Expansion (Updating Configuration Information)]
screen appears and the operation completes successfully, the [Thin Provisioning
Volume Expansion (Result)] screen appears.
If clicking the [Jump to Page], [Next], [Prev], or [Set] button in the
following conditions, an error screen appears. This function
performs the error checking for each page of the Volume List.
Volumes where the capacity will be expanded are displayed with
a yellow background.
-The capacity text box in the Volume List is blank
-A value other than numerals (24 – 33,554,432) has been input
in the capacity text box of Volume List
-A value smaller than the current capacity in the capacity text
box of Volume List
-The total capacity of all Thin Provisioning Volumes in the
ETERNUS DX400/DX8000 series exceeds the maximum Thin
Provisioning Pool capacity for each model
If clicking the [Set] button without expanding the capacity, an error
screen appears.
Available capacity for Thin Provisioning Volume expansion is
displayed in the "Free" field. "Free" capacity is updated when clicking
the [Jump to Page], [Next], [Prev], or [Set] button according to the
input capacity. If an incorrect value is input, "Free" is calculated from
the correct value before changing the capacity. When the total
capacity of all Thin Provisioning Volumes in the ETERNUS DX400/
DX8000 series exceeds the maximum Thin Provisioning Pool
capacity for each model, [0 (MB)] is displayed in the "Free" field.