Chapter 5 Configuration Menu
> 5.4 Host Interface Management
ETERNUS DX400/DX8000 series ETERNUSmgr User Guide Settings/Maintenance
319 Copyright 2010 FUJITSU LIMITED
P2X0-0760-02ENZ0
[Bandwidth Limit]
Set the bandwidth limit (between 10Mbit/s and 400Mbit/s) of the iSCSI-RA Port.
[MTU size]
Set the MTU size for the iSCSI-RA Port.
-1000bytes/1050bytes/1100bytes/1150bytes/1200bytes/1250bytes/1300bytes/
1350bytes/1400bytes/1438bytes
[CHAP]
Select ON (Enabled) or OFF (Disabled) for the CHAP of the iSCSI-RA Port.
-ON
Enables the CHAP.
Enter the user name for the CHAP and the current password.
To change the password, enter a new password.
-OFF
Disables the CHAP.
[Header Digest]
Select the Header Digest for the iSCSI-RA Port from [OFF] or [CRC32C].
[Data Digest]
Select the Data Digest for the iSCSI-RA Port from [OFF] or [CRC32C].
The [Set CA Parameters (iSCSI-RA Detailed Settings Check)] screen appears.
Only set a b andwidth limit (as appropriate) if the line being used
requires one.
When setting the user name and/or the password, check the
"Change" checkbox.