Chapter 6 Settings Menu
> 6.3 Advanced Copy Settings
ETERNUS DX400/DX8000 series ETERNUSmgr User Guide Settings/Maintenance
467 Copyright 2010 FUJITSU LIMITED
P2X0-0760-02ENZ0
5Click the [OK] button.
Returns to the [Menu] screen.
End of procedure
6.3.5 Set Advanced Copy Table Size
This screen is used to set control table size, which is used by the device firmware on CM cach e
memory installed in the device, without stopping the device. When Equivalent Copy (EC), One
Point Copy (OPC), or Remote Equivalent Copy (REC) functions are in use, this control table
(hereafter: Advanced Copy table) is used to manage copy progress. Regardless of the installed
cache memory size, the following capacity is prepared for the Advanced Copy table size in
ETERNUS DX400/DX8000 series.
ETERNUS DX410/DX440: maximum 136MB
ETERNUS DX8100: maximum 136MB
ETERNUS DX8400/DX8700: maximum 528MB
Changes to the Advanced Copy table size and resolution setting will be effective from the next
session.
Copy related menus other than [Register Advanced Copy License] is
not available until the license has been registered.
The purchase of a license and "ETERNUS SF AdvancedCopy
Manager" are necessary in order to use EC/OPC/REC. Register
necessary information by using the [Register Advanced Copy License]
function after purchasing the Advanced Copy license.
When the "Advanced Copy Table size" is "0 [MB]", copy functions (EC/
OPC/REC) are not supported. In the initial setting (factory default),
"Advanced Copy Table Size" is set to "0(MB)".