Chapter 5 Configuration Menu
> 5.4 Host Interface Management
ETERNUS DX400/DX8000 series ETERNUSmgr User Guide Settings/Maintenance
315 Copyright 2010 FUJITSU LIMITED
P2X0-0760-02ENZ0
When clicking the [Set] button in the following conditions, an error
screen appears.
When the required setting items (IP Address, Subnet Mask, iSCSI
Name) are not set.
When characters other than the numbers (0 to 255) are entered in
the IP Address, Subnet Mask, or Gateway.
When a value exceeding the maximum value is set in the IP
Address or Gateway.
When "255.255.255.255" is entered in the IP Address, Subnet
Mask, or Gateway.
When the IP Address is the same as the network address.
When the IP Address is the same as the broadcast address.
When the Gateway has been set, and the IP Address and the
Gateway address are the same.
When the Gateway has been set, and the IP Address and the
Gateway are not in the same subnet.
When the iSCSI Name contains characters other than
alphanumeric characters and symbols ":", "-" and ".".
When the same Alias Name is registered to tw o or m or e iS CS I-
CA Ports.
When the CHAP is ON, and the User Name is 256 characters or
longer.
When the CHAP is ON, and the User Name includes characters
other than 0x20 – 0x7E of ACSII code (alphanumeric characters
and symbols).
When the CHAP is ON, and the Current Password is different
from the data in the device information.
When the CHAP is ON, and the New Password and/or New
Password (Re-enter) include characters other than 0x20 – 0x7E
of ASCII code (alphanumeric characters and symbols).
When the CHAP is ON, and the New Password and the New
Password (Re-enter) are 11 characters or shorter, or 101
characters or longer.
When the CHAP is ON, and the New Password and the New
Password (Re-enter) are not the same.