Chapter 5 Configuration Menu
> 5.3 Thin Provisioning Management
ETERNUS DX400/DX8000 series ETERNUSmgr User Guide Settings/Maintenance
267 Copyright 2010 FUJITSU LIMITED
P2X0-0760-02ENZ0
2Set the thresholds for Thin Provisioning Pool, and click the [Set] button.
There are two thresholds for Thin Provisioning Pools.
Warning
Warning (high) threshold for the target Thin Provisioning Pool (required).
Caution
Warning (low) threshold for the target Thin Provisioning Pool (can be omitted).
The two methods below show how to specify the thresholds.
Manual setting (multiple specification can be made)
Input the threshold (%) in the Warning and Caution text boxes of the Thin Provisioning
Pool List.
Set Range
Enter the first and last Thin Provisioning Pool numbers to set thresholds in the From/To
fields.
Select the threshold types from "Both", "Warning only", or "Caution only".
Input the threshold to be changed in the Warning and Caution text box, and click the
[Execute] button.
The [Set Thin Provisioning Pool Parameters (Check)] screen appears.