Appendix C Syslog Message List
> C.2 Syslog Message List
ETERNUS DX400/DX8000 series ETERNUSmgr User Guide Settings/Maintenance
829 Copyright 2010 FUJITSU LIMITED
P2X0-0760-02ENZ0
The following messages are sent when a temperature error occurs.
P 84SSGGss PP..PP zzzGB DISK(ccccccc) DE#GG/Slot#ss Fault
SSD (Solid State Drive) is disconnected.
P 84SSGGss PP..PP zzzGB DISK(ccccccc) DE#GG/Slot#ss FaildUse
SSD (Solid State Drive) is disconnected.
P 88SSGGss PP..PP zzzGB DISK(ccccccc) DE#GG/Slot#ss Fault
Disk Patrol detects Compare Error. HDD is disconnected.
P 90xxGG0#PBC Fault
PBC is disconnected.
P 9100GG#n PBC PORT Alarm
PBC port is disconnected.
P 9A00GG#n PBC SFP OPTICAL SHORTWAVE Fault
PBC SFP is disconnected.
P 9B00GG#n PBC SFP COPPER Fault
PBC SFP is disconnected.
P 9C00GG0#DEI CABLE Fault
DEI cable error is detected.
P D100GG00 DE FAN UNIT Fault
DE FAN unit is disconnected.
P D2xxGG0#DPSU Fault
DPSU is disconnected.
P D2xxGG0#DPSU Fault(AC Fail)
DPSU is disconnected (when a power failure occurs).
P D300GG0#BBU CABLE Fault
BBU cable error is detected.
P DA00GG0&DE OUT TEMP
DE exhaust temperature error (sensor failure) is detected.
P DB00GG00 DE IN TEMP
DE intake temperature error (sensor failure) is detected.
Event type code Upper: Message
Lower: Description
P 7A00LL0$CE OUT TEMP
CE exhaust temperature error (fatal error) is detected.
P DA00GG0&DE OUT TEMP
DE exhaust temperature error (fatal error) is detected.
Event type code Upper: Message
Lower: Description