Appendix C Syslog Message List
> C.2 Syslog Message List
ETERNUS DX400/DX8000 series ETERNUSmgr User Guide Settings/Maintenance
827 Copyright 2010 FUJITSU LIMITED
P2X0-0760-02ENZ0
Error Message List

The following messages are sent when components fail or degrade.

YYYY Component name of CA
z Capacity (2: 1GB, 4: 2GB, 8: 4GB)
zzz Disk capacity
zzzz Capacity (MB)
Symbol Meaning
Event type code Upper: Message
Lower: Description
P 010xNN00 CM#NN Fault
CM is disconnected.
P 030xNNcc CM#NN DMA PORT Alarm
CM DMA port is disconnected.
P 040xNNcc CM#NN DI Alarm
CM DI is disconnected.
P 0500NNmm CM#NN DI PORT Alarm
CM DI port is disconnected.
P 0600MM00 CM#MM SMC Alarm
SMC is disconnected.
P 0700NN00 CM#NN MMC Alarm
CM MMC is disconnected.
P 0A00MMmm CM#MM DI PORT/PATH Alarm
CM DI port path error is detected.
P 0BzxNNss CM#NN MEMORY(zzzzMB) Fault
CM memory is disconnected.
P 0C0xNN00 CM#NN COMPACT FLASH Fault
CM Compact Flash is disconnected.
P 0D00NN00 CM#NN FAN UNIT Fault
CM FAN unit is disconnected.
P 10wwCC00 CA#CC (on CM#XX) YYYY Fault
CA is disconnected.
P 11wwCCnn CA#CC (on CM#XX) YYYY PORT Alarm
CA port is disconnected.
P 1AwwCCnn CA#CC (on CM#XX) YYYY SFP OPTICAL SHORTWAVE Fault
CA SFP is disconnected.
P 1BwwCCnn CA#CC (on CM#XX) YYYY SFP OPTICAL LONGWAVE Fault
CA SFP is disconnected.
P 1CwwCCnn CA#CC (on CM#XX) YYYY SFP+ Fault
CA SFP+ is disconnected.
P 1DwwCCnn CA#CC (on CM#XX) YYYY SFP OPTICAL LONGWAVE Fault
CA SFP is disconnected.