Chapter 6 Settings Menu
> 6.3 Advanced Copy Settings
ETERNUS DX400/DX8000 series ETERNUSmgr User Guide Settings/Maintenance
468 Copyright 2010 FUJITSU LIMITED
P2X0-0760-02ENZ0
The following explains the setting procedures of Advanced Copy table size.
Procedure
1Click [Set Advanced Copy Table Size] under the Advanced Copy Settings in the
[Settings] menu.
The [Set Advanced Copy Table Size (Initial)] screen appears.
Refer to "A.26.1 Set Advanced Copy Table Size (Initial) Screen" (page 777) for screen
details.
Stop copy sessions (EC/OPC/REC) before decreasing the Advanced
Copy table size. These sessions can be checked by using "ETERNUS
SF AdvancedCopy Manager" or [Advanced Copy Status] function.
When the Advanced Copy table size is not big enough, the Advanced
Copy function cannot be used. Set an appropriate copy capa city as w ell
as appropriate value calculated from the number of operating sessions
for the Advanced Copy table size.
Notice the following points when performing REC between ETERNUS
DX400/DX8000 series and ETERNUS DX400/DX8000 series,
ETERNUS4000, ETERNUS8000, or ETERNUS6000.
-Set the "Resolution" of the devices which will be defined as copy
source / copy destination to the same value. When the "Resolution"
settings of the devices of copy source / copy d estination are
different, an error will occur when performing REC. It is not required
to set "Advanced Copy table size" to the same value.
When the "Resolution" calculated in the devices of copy source /
copy destination are different, adjust the "Resolution" to the larger
value. In this case, recalculate and set the "Advanced Copy table
size" of the device in which "Resolution" was changed.
Notice the following points when performing REC between ETERNUS
DX400/DX8000 series and ETERNUS3000.
-The copy source and copy destination devices must be set the same
"Resolution" value.
The resolutions of the ETERNUS DX410/DX440, ETERNUS
DX8100/DX8400/DX8700, and ETERNUS3000 correspond as
follows:
*1: Resolution "1" for the ETERNUS DX400/DX8000 series corresponds to
resolution "16" of the ETERNUS3000.
*2: If resolution "16" is set for the ETERNUS DX400/DX8000 series, it is
impossible to connect to the ETERNUS3000.
Model Corresponding resolution (*1)
ETERNUS DX410/DX440 1 2 4 8 16
ETERNUS DX8100/DX8400/
DX8700
124816
ETERNUS3000
model 300/500/700
16 32 64 128 (*2)