Appendix C Syslog Message List
> C.2 Syslog Message List
ETERNUS DX400/DX8000 series ETERNUSmgr User Guide Settings/Maintenance
831 Copyright 2010 FUJITSU LIMITED
P2X0-0760-02ENZ0
Warning Message List

The following messages are sent when the battery reaches its expiration date, when compo-

nents require maintenance or preventive maintenance, for unusual temperatures, and for other

warning events.

zzz Disk capacity
zzzz Capacity (MB)
Symbol Meaning
Event type code Upper: Message
Lower: Description
J 010xNN00 CM#NN Warning
CM error (statistics or other error) is detected.
J 010xNN00 CM#NN MCE Correctable Error
CM error (correctable error) is detected.
J 010xNN00 CM#NN FACTOR (00hh)
CM error other than above is detected.
J 0600MM00 CM SMC
CM SMC error is detected.
J 0C0xNN00 CM#NN COMPACT FLASH Warning
CM Compact Flash error is detected.
J 10wwCC00 CA#CC (on CM#XX) YYYY Warning
CA error is detected.
J 40xxFF00 FRT Warning
FRT error is detected.
J 5000BB00 BRT Warning
BRT error is detected.
J 6000EE00 SVC
SVC error is detected.
J 7006ss00 BATTERY * 6MONTH WARNING YYYY/MM
6 months before the battery expiration date.
When there are multiple batteries with the same expiration date, other Slot
numbers are also reported with the smallest Slot number (*1).
J 7007ss00 BATTERY * 1WEEK WARNING YYYY/MM
1 week before the battery expiration date.
When there are multiple batteries with the same expiration date, other Slot
numbers are also reported with the smallest Slot number (*1).
J 7007ss00 BATTERY * zDAY WARNING YYYY/MM
z days before the battery expiration date.
When there are multiple batteries with the same expiration date, other Slot
numbers are also reported with the smallest Slot number (*1).
J 70FEss00 BATTERY * EXPIRATION ALARM YYYY/MM
Battery expiration date has passed.
When there are multiple batteries with the same expiration date, other Slot
numbers are also reported with the smallest Slot number (*1).