Fujitsu RX600 S5 manual Hot-plug components

Models: RX600 S5

1 148
Download 148 pages 12.99 Kb
Page 106
Image 106

Hot-plug components

CSS components

ÊIf you want to remove an HDD module that is not defective, the drive must be first set to "Offline" via the software (RAID controller configuration software).

ÊUnlock the HDD module as described in section "Installing the HDD module" on page 104.

ÊPull the HDD module out a few centimeters.

ÊWait for at least 60 seconds.

IThis period is necessary for the RAID controller to recognize that an HDD module has been removed and for the hard disk drive to come to a stop.

ÊPull the HDD module out completely.

ÊInstall the new HDD module, as described in "Installing the HDD module" on page 104.

VCAUTION!

If you have removed an HDD module and do not install a new one in its place, put the dummy module back in its place for cooling, to comply with EMC regulations (regulations regarding electromagnetic compatibility), and for protection against fire. Ensure that the dummy module engages correctly in the bay.

106

Operating Manual

RX600 S5

Page 106
Image 106
Fujitsu RX600 S5 manual Hot-plug components