Notes on installing the server in the rack | Important information |
3.6Notes on installing the server in the rack
VCAUTION!
●For safety reasons, at least two people are required to install the server in the rack because of its weight and size.
(For the Japanese market, please refer to " 安全上の注意およびその 他の重要情報 ".)
●Never lift the server into the rack using the handles on the front panel.
●When connecting and disconnecting cables, observe the relevant instructions in the "Important Information" chapter of the technical manual for the corresponding rack. The technical manual is supplied with the corresponding rack.
●When installing the rack, make sure that the
●For safety reasons, no more than one unit may be removed from the rack at any one time during installation and maintenance work.
●If several units are simultaneously removed from the rack, there is a risk that the rack could tip over.
●The rack must be connected to the power supply by an authorized specialist (electrician).
●If the server is integrated into an installation that draws power from an industrial power supply network with an IEC309 type connector, the power supply's fuse protection must comply with the requirements for
38 | Operating Manual | RX600 S5 |