CSS components

Hot-plug components

8.1.2Hot-plug fans

The server comes with four hot-plug fans (eight fans only in a redundant configuration). Each fan is mounted in a fan module that is accessible from the top when opening the server.

A possible fan failure is reported by the CSS indicator lighting up on the front and rear of the server as well as by the indicator on the fan module in question.

The fan failure is also displayed on the ServerView Local Service Display (see the "Customer Self Service (CSS)" manual on the ServerView Suite DVD 2).

Identifying the defective CSS component

ÊOpen the server (see "Opening/Closing the server" on page 134).

The defective fan is identified from the indicator on each fan (see figure 21 on page 97).

Figure 21: Indicator on a hot-plug fan