Preface
Mechanical specifications
| Floorstand | Rack |
|
|
|
Width (with | 205 mm (306 mm) | 482 mm |
|
|
|
Total depth | 584 mm | 570 mm |
|
|
|
Installation depth | 596 mm | |
|
|
|
Height | 444 mm | 5 HU |
|
|
|
Dimension notes | Floorstand width 306 mm with tilt protection; | |
| depth measured excludes handles on redundant | |
| PSU. Rack depth excludes handles of | |
| redundant PSU and rack front. | |
|
|
|
Weight
max. 36.8 kg (depending on configuration).
Ventilation clearance
At least 200 mm on the front and rear.
Maintenance area for the floorstand model
1.2 m2 on the left side. Emergency access must be assured.
Ambient conditions
Environment class 3K2 | EN 60721 / IEC 721 Part |
Environment class 2K2 | EN 60721 / IEC 721 Part |
|
|
Temperature: |
|
Operation (3K2) | 10 °C .... 35 °C |
Transport (2K2) | |
|
|
Humidity | 10% .... 85% (non condensing) |
|
|
Condensation during operation must be avoided!
TX200 S6 | Operating Manual | 27 |