Fujitsu V01 manual Data Port Setting Items

Models: V01

1 138
Download 138 pages 23.38 Kb
Page 43
Image 43

Chapter 3 Web Operation

After the completion of the settings, click the button. The message below appears. Click OK to apply the settings. *Reboot is not required.

Table 3-7 Data Port Setting Items

 

Item

Description

Parameter

Operation

Data port

Specify whether to use data port

- Enable

settings

 

communication.

- Disable (Default)

 

Operation mode

Specify the operation mode of data

- TCP server mode (bidirectional)

 

 

port communication.

(Default)

 

 

 

- TCP server mode (receiving only)

 

 

 

- TCP client mode (bidirectional)

 

IP version

Set the IP address version

- IPv4 (Default)

 

 

 

- IPv6

 

Destination IP

Specify the IP address of the data

- IPv4 (Default)

 

address

communication destination when

- IPv6

 

 

"TCP client mode (bidirectional)" is

 

 

 

set for [Test mode].

 

 

 

Specify the IP address of the data

Other than 0.0.0.0

 

 

communication destination when

(Default: 0.0.0.0)

 

 

"TCP client mode (bidirectional)" is

 

 

 

set for [Test mode].

 

Port number

Server mode

Specify the port number of the own

1024 to 64000

settings

 

device when "TCP server mode

(Default: 6000)

 

 

(bidirectional)" is set for [Test mode].

 

 

Client mode

Specify the port number of the own

0 or 1024 to 64000

 

 

device when "TCP client mode

(Default: 0)

 

 

(bidirectional)" is set for [Test mode].

* If o is specified, a port number from

 

 

 

1024 to 4096 is automatically selected.

 

 

Specify the port number of the

1024 to 64000

 

 

destination device when "TCP client

(Default: 6000)

 

 

mode (bidirectional)" is set for [Test

 

 

 

mode].

 

RS-232C

Timeout

Specify in milliseconds the reception

20 to 200ms (Default: 20)

settings

 

timeout time for RS-232C.

* The duration to detect a time-out is

 

 

 

defined as "the set value rounded down

 

 

 

by a multiple of '20[ms]'" + "RS-232C

 

 

 

polling interval of the device (20[ms])".

 

 

 

ex)

 

 

 

When '60' is set, the duration will be

 

 

 

'60' + '20' = 80 [ms]

 

 

 

When '50' is set, the duration will be

 

 

 

'40' + '20' = 60 [ms]

IP-900 Series

37

Page 43
Image 43
Fujitsu V01 manual Data Port Setting Items