Chapter 3 Web Operation
After the completion of the settings, click the button. The message below appears. Click OK to apply the settings. *Reboot is not required.
Table 3-7 Data Port Setting Items
| Item | Description | Parameter |
Operation | Data port | Specify whether to use data port | - Enable |
settings |
| communication. | - Disable (Default) |
| Operation mode | Specify the operation mode of data | - TCP server mode (bidirectional) |
|
| port communication. | (Default) |
|
|
| - TCP server mode (receiving only) |
|
|
| - TCP client mode (bidirectional) |
| IP version | Set the IP address version | - IPv4 (Default) |
|
|
| - IPv6 |
| Destination IP | Specify the IP address of the data | - IPv4 (Default) |
| address | communication destination when | - IPv6 |
|
| "TCP client mode (bidirectional)" is |
|
|
| set for [Test mode]. |
|
|
| Specify the IP address of the data | Other than 0.0.0.0 |
|
| communication destination when | (Default: 0.0.0.0) |
|
| "TCP client mode (bidirectional)" is |
|
|
| set for [Test mode]. |
|
Port number | Server mode | Specify the port number of the own | 1024 to 64000 |
settings |
| device when "TCP server mode | (Default: 6000) |
|
| (bidirectional)" is set for [Test mode]. |
|
| Client mode | Specify the port number of the own | 0 or 1024 to 64000 |
|
| device when "TCP client mode | (Default: 0) |
|
| (bidirectional)" is set for [Test mode]. | * If o is specified, a port number from |
|
|
| 1024 to 4096 is automatically selected. |
|
| Specify the port number of the | 1024 to 64000 |
|
| destination device when "TCP client | (Default: 6000) |
|
| mode (bidirectional)" is set for [Test |
|
|
| mode]. |
|
Timeout | Specify in milliseconds the reception | 20 to 200ms (Default: 20) | |
settings |
| timeout time for | * The duration to detect a |
|
|
| defined as "the set value rounded down |
|
|
| by a multiple of '20[ms]'" + |
|
|
| polling interval of the device (20[ms])". |
|
|
| ex) |
|
|
| When '60' is set, the duration will be |
|
|
| '60' + '20' = 80 [ms] |
|
|
| When '50' is set, the duration will be |
|
|
| '40' + '20' = 60 [ms] |
IP-900 Series