Fujitsu V01 manual Operation Modes, Operation mode Description

Models: V01

1 138
Download 138 pages 23.38 Kb
Page 44
Image 44

Chapter 3 Web Operation

 

Item

 

 

Description

 

 

 

Parameter

 

Delimiter code 1

Specify

the

delimiter

code

1

for

Blank or hexadecimal number between

 

 

RS-232C.

 

 

 

 

00 and ff

 

 

 

 

 

 

 

 

(Default: Blank)

 

 

 

 

 

 

 

 

* A blank field means that no value is

 

 

 

 

 

 

 

 

specified.

 

Delimiter code 2

Specify

the

delimiter

code

2

for

Blank or hexadecimal number between

 

 

RS-232C.

 

 

 

 

00 and ff

 

 

 

 

 

 

 

 

(Default: Blank)

 

 

 

 

 

 

 

 

* A blank field means that no value is

 

 

 

 

 

 

 

 

specified.

 

Baud rate

Specify the RS-232C communication

1200/2400/4800/9600 (Default)

 

 

speed.

 

 

 

 

 

/19200/38400 bps

 

 

 

 

 

Bit length

Specify the RS-232C character size.

7 bits or 8 bits (Default)

 

Parity

Specify whether to use RS-232C

None (Default), Odd or Even

 

 

parity.

 

 

 

 

 

 

 

Stop bits

Specify the length of RS-232C stop

1 bit (Default) or 2 bits

 

 

bits.

 

 

 

 

 

 

 

Flow control

Specify whether to set RS-232C flow

None (Default), RS or CS

 

 

control.

 

 

 

 

 

 

Table 3-8 Operation Modes

Operation mode

Description

(1)

 

Bidirectional data communication is performed between the data port and

 

TCP server mode

another device connected via the IP network. IP-900 series waits, at the

 

(bidirectional)

specified port number, for access through socket connection from the

 

 

destination device. (IP address setting is not required.)

(2)

 

Data received from another device connected via the IP network is output to

 

TCP server mode

the data port. Data received from the data port is not sent to the destination.

 

(receiving only)

IP-900 series waits, at the specified port number, for access through socket

 

 

connection from the destination device. (IP address setting is not required.)

(3)

 

Bidirectional data communication is performed between the data port and

 

TCP client mode

another device connected via the IP network. IP-900 series sets up a socket

 

(bidirectional)

connection through the specified port to the device with the specified IP

 

 

address.

*The following combinations of modes are available for data communication between IP-900 series:

(1)<-> (3)

(2)<-> (3)

IP-900 Series

38

Page 44
Image 44
Fujitsu V01 manual Operation Modes, Operation mode Description