Chapter 3 Web Operation

After the completion of the settings, click the button. The message below appears. Click OK to apply the settings. * Reboot is not required.

Table 3-23 Setting Items for Encoder Address Report

 

Item

 

Description

 

 

Value

Main

Encoder name

Specify an arbitrary name

Up to 16 characters

encoder

 

 

 

used to identify the encoder.

 

report

 

 

 

 

 

 

 

 

settings

 

 

 

 

 

 

 

 

 

Local port

 

Specify the own device port

0 or 1024 to 64000 (Default: 0)

 

 

 

 

number used to send an

* If 0 is specified, one of the port numbers

 

 

 

 

encoder address message.

 

from 64100 to 65000 is automatically selected.

Main

Destinat

 

IP version

Specify the IP version of the

- IPv4 (default)

encoder

ion 1 to

 

 

IP address of the destination

- IPv6

destination

10

 

 

device to which the encoder

 

settings

 

 

 

report is to be sent.

 

 

 

 

 

IP address

Specify the IP address of the

Other than 0.0.0.0

 

 

 

 

destination device to which

(Default: Blank)

 

 

 

 

the encoder report is to be

* A blank field means that no value is

 

 

 

 

sent.

 

 

 

specified.

 

 

 

 

 

 

 

 

* A multicast address cannot be set.

 

 

 

Destination

Specify the port number of

- Blank or 1024 to 64000

 

 

 

port

the

destination

device

to

(Default: Blank)

 

 

 

 

which the encoder report is

* A blank field means that no value is

 

 

 

 

to be sent.

 

 

specified.

Sub encoder

Encoder

name

Specify an arbitrary name

Up to 16 characters

report

 

 

 

used to identify the encoder.

 

settings

 

 

 

 

 

 

 

 

 

Local port

 

Specify the own device port

0 or 1024 to 64000 (Default: 0)

 

 

 

 

number used to send an

* If 0 is specified, one of the port numbers

 

 

 

 

encoder address message.

 

from 64100 to 65000 is automatically selected.

Sub encoder

Destinat

 

IP version

Specify the IP address of the

- IPv4 (Default)

destination

ion 1 to

 

 

destination device to which

- IPv6

settings

10

 

 

the encoder report is to be

 

 

 

 

IP address

sent.

 

 

 

Other than 0.0.0.0

 

 

 

 

 

 

 

 

(Default: Blank)

 

 

 

 

 

 

 

 

* A blank field means that no value is

 

 

 

 

 

 

 

 

specified.

 

 

 

 

 

 

 

 

* A multicast address cannot be set.

 

 

 

Destination

Specify the port number of

- Blank or 1024 to 64000

 

 

 

port

the

destination

device

to

(Default: Blank)

 

 

 

 

which the encoder report is

* A blank field means that no value is

 

 

 

 

to be sent.

 

 

specified.

IP-900 Series

86

Page 92
Image 92
Fujitsu V01 manual Setting Items for Encoder Address Report