Fujitsu V01 manual 116

Models: V01

1 138
Download 138 pages 23.38 Kb
Page 122
Image 122

Chapter 4 Troubleshooting

Code

Name

Description

Details (The part after the * mark is not displayed.)

E013

Temperature warning (*2)

Thermal alarm (alarm only) detected

#1 TEMP1=t1 TEMP2=t2 FAN=xxxRPS

 

 

 

#2 TEMP1=t1 TEMP2=t2 FAN=xxxRPS

 

 

 

* Details are as follows:

 

 

 

#1/#2: Number of the temperature sensor that has

 

 

 

detected a thermal alarm

 

 

 

t1: Temperature indicated by temperature sensor 1

 

 

 

t2: Temperature indicated by temperature sensor 2

 

 

 

xxx: FAN rotational speed

*E013

Thermal alarm recovery (*2)

Recovered from thermal alarm

#1 TEMP1=t1 TEMP2=t2 FAN=xxxRPS

 

 

 

#2 TEMP1=t1 TEMP2=t2 FAN=xxxRPS

 

 

 

* Details are as follows:

 

 

 

#1/#2 : Number of the temperature sensor that has

 

 

 

detected a thermal alarm recovery

 

 

 

t1: Temperature indicated by temperature sensor 1

 

 

 

t2: Temperature indicated by temperature sensor 2

 

 

 

xxx: FAN rotational speed

E082

CODEC1 error (*4)

Main HD CODEC LSI error detected

*E082

CODEC1 error recovery (*4)

Recovered from main CODEC LSI error

E083

CODEC2 error (*4)

Sub CODEC LSI error detected

*E083

CODEC2 error recovery (*4)

Recovered from sub CODEC LSI error

E084

CF card access error (*3)

CF card access failure detected

E085

CF card power error (*3)

Overcurrent to CF card detected

E08B

SUB CPU1 error (*4)

SUB CPU1 error detected

*E08B

SUB CPU1 error recovery (*4)

Recovered from SUB CPU1 error

E08C

SUB CPU2 error (*4)

SUB CPU2 error detected

*E08C

SUB CPU2 error recovery (*4)

Recovered from SUB CPU2 error

E08E

Clock error (*1)

Clock error or interruption detected

#1 to #4 * Indicates the location where a clock error

 

 

 

has occurred.

E08F

Memory error (*1)

SDRAM memory check error detected

#1 to #7 * Indicates the location where a memory error

 

 

 

has occurred.

E093

Sending buffer overflow (*7)

Sending buffer overflow occurred

#1, #2 * Indicates the location where a sending buffer

 

 

 

overflow has occurred.

IP-900 Series

116

Page 122
Image 122
Fujitsu V01 manual 116