Chapter 3 Web Operation
Code | Name | Description | Details (The part after the * mark is not displayed.) |
E013 | Temperature warning (*2) | Thermal alarm (alarm only) detected | #1 TEMP1=t1 TEMP2=t2 FAN=xxxRPS |
|
|
| #2 TEMP1=t1 TEMP2=t2 FAN=xxxRPS |
|
|
| * Details are as follows: |
|
|
| #1/#2: Number of the temperature sensor that has |
|
|
| detected a temperature error |
|
|
| t1: Temperature indicated by temperature sensor 1 |
|
|
| t2: Temperature indicated by temperature sensor 2 |
|
|
| xxx: FAN rotational speed |
E082 | CODEC1 error (*4) | Main CODEC LSI error detected | - |
E083 | CODEC2 error (*4) | Sub CODEC LSI error detected | - |
E084 | CF card access error (*3) | CF card access failure detected | - |
E085 | CF card power error (*3) | Overcurrent to CF card detected | - |
E08B | SUB CPU1 error (*4) | SUB CPU1 error detected | - |
E08C | SUB CPU2 error (*4) | SUB CPU2 error detected | - |
E08E | Clock error (*1) | Clock error or interruption detected | #1 to #4 * Indicates the location where a clock error |
|
|
| has occurred. |
E08F | Memory error (*1) | SDRAM memory check error detected | #1 to #7 * Indicates the location where a memory |
|
|
| error has occurred. |
E093 | Sending buffer overflow (*6) | Sending buffer overflow occurred | #1, #2 * Indicates the location where a sending buffer |
|
|
| overflow has occurred. |
If an alarm recovers occurs after an alarm occurrence.
*1: After occurrence of this error, the ALM LED remains on. The device needs to be rebooted to turn off the ALM LED.
*2: The ALM LED blinks while this alarm is active. The LED goes off when the alarm cause is recovered.
*3: After occurrence of this error, the ALM LED remains to blink.
*4: After occurrence of this error, the operation is retired for recovery. If the retry for recovery is unsuccessful, the ALM LED remains on. The device needs to be rebooted to turn off the ALM LED.
*5: If an extreme temperature is detected, all LEDs except LINK/ACT, 10/100 go on. The device needs to be rebooted to turn off the LEDs.
*6: The ALM LED blinks while this alarm is active. The LED goes off when the alarm cause is recovered.
In case that the settings exceeds the capacity of the IP network, please reconfigure them to meet the network requirement
*7: The IN DWN LED blinks while this alarm is active. The LED goes off 10 seconds after the error cause is recovered. See 3. 2. 11 Performance Statistics for the details of the statistical information counter about the alarm occurrence.
IP-900 Series