4. VIDEO SOUNDER OPERATION

4.12Alarms

The sounder section has five conditions which generate visual and aural alarms: bottom alarm, fish alarm (bottom lock), fish alarm (normal) and water temperature alarm (temperature sensor required). For 1722C/1723C series, note that the alarm icon is red when an alarm setting is violated, and changes to background color when the [CLEAR] key or CLEAR ALARM soft key is pressed. The color does not change when another alarm is violated.

You may set up the sounder alarms on the ALARM menu, which may be displayed by pressing the [ALARM] key.

AUDIO ALARM INTERNAL BUZZ

BOTTOM ALARM OFF

TEMPERATURE ALARM

OFF

FISH ALARM

OFF

FISH ALARM (B/L)

OFF

ALARM INFOMATION

NO ALARM

SOUNDER ALARM

EDIT

CLEAR

ALARM

RETURN

Sounder alarm menu

4.12.1Audio alarm on/off

The audio alarm sounds whenever an alarm setting is violated. You can enable or disable the audio alarm as follows:

1.Press the [ALARM] key to show the ALARM menu.

2.Use the cursor pad to select AUDIO ALARM.

3.Press the EDIT soft key to show the audio alarm window.

AUDIO ALARM

§INT & EXT BUZZ °INTERNAL BUZZ

OFF

Audio alarm window

4.Use the cursor pad to select INT & EXT BUZZ (Internal + External alarm), INTERNAL BUZZ (Internal alarm) or OFF. This turns on or off the audio alarm for all modes globally, including radar.

5.Press the ENTER soft key.

6.Press the [ALARM] key to finish.

4-19

Page 165
Image 165
Furuno 1732C, 1753C, 1733C, 1723C, 1762C, 1722C, 1763C, 1752C, 1742C manual Alarms, Sounder alarm menu