1. OPERATIONAL OVERVIEW

1.6.4Selecting radar source

When other network radar is connected to the equipment, you may select an image source as shown below. This is not necessary when no other network radar is connected. Select one host name for the source though there are two or three radar units on the net.

Note: Turn the power off whenever changing the source.

1.Press the [DISP] key.

2.Press any soft key to show the following display.

RADAR SOURCE

RADAR - - -

SOUNDER SOURCE* SOUNDER-

IP ADDRESS 172.031.003.001

HOST NAME RADAR - - -

SELECT SOURCE

EDIT

IF THERE IS MORE THAN ONE NETWORK RADAR OR ECHO SOUNDER, YOU MAY SELECT THE IMAGE SOURCES FOR DISPLAY.

RETURN

*: Do not change this setting.

Select source menu

3. Use the cursor pad to select RADAR SOURCE and press the EDIT key.

RADAR SOURCE

RADAR - - -

Radar source

Radar source and sounder source windows

4.Use the cursor pad and [ENTER] knob to enter source host name: ◄ or ► to select position and rotate the [ENTER] knob to select character.

5.Press the [ENTER] soft key or [ENTER] knob.

6.Confirm that the correct host name is entered.

7.Press the [DISP] key to finish.

8.Turn the power off and on again.

Note: Sources names are determined at installation. For example, the source names for radars in a two radar system might be “RADAR” and “RADAR1”.