2. RADAR OPERATION

2.25.8CPA/TCPA alarm (ARP)

When the predicted CPA of any target becomes smaller than a preset CPA alarm range or its predicted TCPA less than a preset TCPA alarm limit, an audio alarm sounds, which you may silence with the [CLEAR] key. In addition, the target plot symbol of the offending target changes to a triangle and flashes together with its vector. Press the [ALARM] key and the message COLLISION ALARM appears.

Press the CLEAR ALARM soft key to acknowledge the alarm. The flashing of the triangle plot symbol continues until you intentionally terminate tracking of the target. The ARP continuously monitors the predicted range at the Closest Point of Approach (CPA) and predicted time to CPA (TCPA) of each target to own ship.

Provided that this feature is used correctly, it will help prevent the risk of collision by alerting you to threatening targets. It is important that gain, A/C SEA, A/C RAIN and other radar controls are properly adjusted and the ARP is set up so that it can track targets effectively.

CPA/TCPA alarm ranges must be set up properly taking into consideration the size, tonnage, speed, turning performance and other characteristics of own ship.

CAUTION

The CPA/TCPA alarm should never be relied upon as the sole means for detect- ing the risk of collision. The navigator is not relieved of the responsibility to keep visual lookout for avoiding collisions, whether or not the radar or other plotting aid is in use.

Follow the steps shown below to set the CPA/TCPA alarm range:

1.Press the [MENU] key followed by the ARP SETUP soft key.

2.Operate the cursor pad to select CPA.

3.Press the EDIT soft key to show the CPA window.

CPA

°￿

§OFF 0.5nm 1nm 2nm 3nm 5nm

6nm

CPA window

4.Select a CPA limit desired by the cursor pad.

5.Press the ENTER soft key. The ARP SETUP menu reappears.

6.Press the cursor pad to select TCPA.

7.Press the EDIT soft key to show the TCPA window.

2-42

Page 76
Image 76
Furuno 1762C, 1753C, 1733C, 1723C, 1722C, 1763C, 1732C, 1752C, 1742C manual 25.8 CPA/TCPA alarm ARP, CPA window